IST1347I
INSUFFICIENT STORAGE TO DELAY DISCONNECT OF puname

Explanation

VTAM® issues this message when there is insufficient storage to delay the disconnection of a physical unit that was defined as DISCNT=DELAY.

puname is the name of the physical unit being disconnected.

System action

VTAM will attempt to disconnect the physical unit without delay.
  • If message IST169I is issued for the same physical unit, the disconnection without delay was successful.
  • If message IST348I is issued for the same physical unit, there was insufficient storage to disconnect the physical unit even without delay.

Operator response

  • If message IST169I follows this message, no action is required.
  • If message IST348I follows IST1347I, enter a VARY INACT, TYPE=FORCE command for puname.
  • If you have frequent command failures because of insufficient storage:
    • Issue the DISPLAY BFRUSE command. Message IST981I displays total VTAM private storage information. Issue the DISPLAY STORUSE command to display storage usage for storage pools.
    • Save the system log and request a console dump for problem determination.

System programmer response

If insufficient storage is a recurring problem, you may need to increase storage as required.

See z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures for information on storage-related problems.

See the z/OS Communications Server: SNA Operation for more information.

Routing code

2

Descriptor code

5