Explanation
This message is part of a group of messages that VTAM® issues in response to a DISPLAY
ID command for an NCP frame relay switching equipment set (FRSESET)
or an NCP frame relay physical unit. Possible message groups follow.
- If the FRSESET statement was coded, the following message group
is issued.
IST075I NAME = frsesetname, TYPE = STATIC FRSESET
IST1289I FRSESET frsesetname PHYSICAL UNITS:
IST080I primary_pu1 status primary_pu2 status
[IST080I [backup_pu1 status] [backup_pu2 status]]
IST314I END
- If the FRSESET statement was added dynamically using the VARY ACT,UPDATE=ALL
command, the following message group is issued.
The second message
in this group is IST1290I, IST1291I, IST1292I, or IST1294I, and indicates
whether the FRSESET has been sent to the NCP.
IST075I NAME = frsesetname, TYPE = DYNAMIC FRSESET
[IST1290I FRSESET HAS BEEN SUCCESSFULLY SENT TO NCP ncpname]
[IST1291I FRSESET WILL BE SENT TO THE NCP DURING PU ACTIVATION]
[IST1292I FRSESET WILL NOT BE SENT TO THE NCP DUE TO DEFINITION ERROR]
[IST1294I FRSESET HAS BEEN SENT TO NCP ncpname BUT FAILURE OCCURRED]
IST1289I FRSESET frsesetname PHYSICAL UNITS:
IST080I primary_pu1 status primary_pu2 status
[IST080I [backup_pu1 status] [backup_pu2 status]]
IST314I END
- If the display is for an NCP frame relay physical unit, the following
message group is issued.
IST075I NAME = puname, TYPE = PU_T1
IST486I STATUS = currentstatus, DESIRED STATE = desiredstate
IST081I LINE NAME = linename, LINE GROUP = linegroup, MAJNOD = majnode
IST1289I FRSESET frsesetname PHYSICAL UNITS:
IST080I primary_pu1 status primary_pu2 status
[IST080I [backup_pu1 status] [backup_pu2 status]]
IST654I I/O TRACE = {ON|OFF}, BUFFER TRACE = {ON|OFF}
IST355I LOGICAL UNITS:
IST080I nodename1 status1 nodename2 status2 nodename3 status3
IST314I END
IST075I - In message groups 1 and 2, frsesetname is
the name of the NCP frame relay switching equipment set (FRSESET)
specified on the ID operand of the command.
- In message group 3, puname is the name of
the physical unit specified on the ID operand of the command and is
always a PU type 1.
IST080I - If this message follows IST1289I, it displays the names of the
primary and backup physical units defined for FRSESET frsesetname.
- Backup PUs are optional, and one or both backup PUs can be specified.
If only one backup PU is specified, VTAM displays
the name and status of the specified backup PU and leaves the other
field blank. If no backup PUs are specified, the message is not displayed.
- primary_pu1 is the name of the first PU specified
on the SUBPORTS operand of the FRSESET definition statement.
- primary_pu2 is the name of the second PU specified
on the SUBPORTS operand of the FRSESET definition statement.
- backup_pu1, if specified, is the name of the
third PU on the SUBPORTS operand of the FRSESET definition statement. backup_pu1 is
the backup PU for primary_pu1.
- backup_pu2, if specified, is the name of the
fourth PU on the SUBPORTS operand of the FRSESET definition statement. backup_pu2 is
the backup PU for primary_pu2.
- If this message follows IST355I, nodename is
the name of a logical unit.
- status is the status of the resource that is
displayed. See Resource Status Codes and Modifiers inz/OS Communications Server: IP and SNA Codes for a description of these status codes.
IST081I - linename is the line to which majnode is
connected.
- groupname is the line group to which the line linename belongs.
- majnode is the major node with which the line
is associated.
IST355I - This message is a header message for IST080I when logical units
and their status are displayed.
IST654I - This message indicates whether the I/O trace facility is active
or inactive for puname in message IST075I, and
whether the buffer trace facility is active or inactive for puname.
IST1289I - frsesetname is the name of the FRSESET definition
statement displayed in message IST075I.
IST1290I - This message confirms that FRSESET frsesetname has
been successfully sent to NCP ncpname.
- ncpname is the name of the NCP that received
FRSESET frsesetname.
IST1291I - This message indicates that FRSESET frsesetname is
valid and will be sent to the NCP when all PUs in the FRSESET have
received positive RNAA responses.
IST1292I - This message indicates that FRSESET frsesetname will
not be sent to the NCP. The FRSESET is not valid because of a definition
error in the FRSESET or one of the PUs. Messages issued prior to this
message group provide additional information about the error.
IST1294I - This message indicates that even though FRSESET frsesetname has
been sent to NCP ncpname, a failure occurred that
prevented successful completion.
- ncpname is the name of the NCP that rejected
FRSESET frsesetname.
- Either message IST380I or message IST1139I will be issued prior
to this message group to provide additional information about the
cause of the failure.
System action
Processing continues.
- If IST1291I is displayed, the FRSESET will be sent to the NCP
when all PUs in the FRSESET have received positive RNAA responses.
- If IST1292I is displayed, the PUs may or may not become active.
You can monitor this by checking the PU status in
message IST080I.
- If IST1294I is displayed, VTAM deactivates
the PUs in frsesetname.
Operator response
None, except in the following situations:
- If IST1291I is displayed, ensure that all the PUs in the FRSESET
have been activated.
- If IST1292I or IST1294I is displayed, save the system log for
problem determination.
System programmer response
None, except in the following situations:
- If IST1292I is displayed, correct the definition errors in the
FRSESET or the PUs. Then add new PUs to the FRSESET using dynamic
reconfiguration.
- If IST1294I is displayed, correct the error indicated by the sense
code in message IST380I or IST1139I. Then add new PUs to the FRSESET
using dynamic reconfiguration.
For more information on the FRSESET definition statement,
see the NCP, SSP, and EP Resource Definition Reference
For
information on dynamic reconfiguration, see the z/OS Communications Server: SNA Network Implementation
Guide.
Routing code
Descriptor code