IST1137I
command FAILED, nodenamereason

Explanation

VTAM® issues this message when the command failed for the specified reason.

If a network-qualified name was entered on the command line, VTAM issues nodename in the form netid.name.

reason indicates the cause of the failure and can be one of the following:
ALSNAME NOT GIVEN
A MODIFY TRACE,TYPE=GPT command was entered for nodename. No ALSNAME was specified, and a default ALSNAME could not be determined because of one of the following:
  • The adjacent link station list for nodename contains no entries.
  • The adjacent link station list for nodename contains two or more entries (other than ISTAPNPU).
ALSNAME NOT VALID
A MODIFY TRACE,TYPE=GPT command was entered for nodename. The adjacent link station name (ALSNAME) that was either specified or used by default was not in a valid state when the command was entered. If ISTAPNPU was used by default because it was the only entry in the adjacent link station list, then this is the reason the command failed. ISTAPNPU is the name of the generic APPN adjacent link station. A real adjacent link station name must be specified for the command to succeed.
ARM REJECTED
A MODIFY TRACE command or TRACE start option was specified with the value TYPE=QDIOSYNC. An Arm request was initiated and the reply indicates that the OSA-Express2 or later adapter supports the QDIOSYNC function, but an error occurred while attempting to arm the OSA-Express2 or later adapter.
CDRSC IS DYNAMIC
nodename is a dynamic cross-domain resource; this is not valid for the TRACE command you entered.
CDRSC NOT ACTIVE
Giveback processing or internal delete for node nodename failed. VTAM found a predefined CDRSC to be not active, and VTAM was not able to transfer the active sessions from the LU to the CDRSC.
CDRSC NOT ALLOCATED
Giveback processing or internal delete for node nodename failed. VTAM has insufficient resources to allocate a cross-domain resource or does not support a dynamic CDRSC and was not able to transfer the active sessions from the LU to a CDRSC.
DEACTIVATE PENDING
VTAM rejected a VARY INACT, TYPE=GIVEBACK or VARY REL, TYPE=GIVEBACK command because a logical unit subordinate to nodename has LU-LU sessions and is pending deactivation.
EXIT IS NOT FOUND
The operator entered a DISPLAY EXIT command for a VTAM installation-wide exit which could not be located.
INSTALL EXIT REJECT
The operator entered a MODIFY ENCR command for nodename, and VTAM rejected the MODIFY ENCR command because of user-written routines related to the GENKEY function.
INSTALL PROGRAM
A MODIFY ENCR command was entered for nodename and the cryptographic facility is not supported by this host.
ISTLSXCF NOT ACTIVE
Another node in the sysplex attempts to establish a connection with an XCF node, but the connection is not established because the dynamic local SNA major node, ISTLSXCF, is not in an active state.
ISTLSXCF NOT FOUND
Another node in the sysplex attempts to establish a connection with an XCF node, but the connection is not established because the dynamic local SNA major node, ISTLSXCF, does not exist.
ISTTRL NOT FOUND
Another node in the sysplex attempts to establish a connection with an XCF node, but the connection is not established because the TRL major node, ISTTRL, does not exist.
MACLNTH NOT VALID
The operator entered a MODIFY SECURITY command with a MACLNTH value that is not valid. The MACLNTH value is dependent on the most recent specification of MACTYPE. The MACTYPE value might have been specified on a MODIFY SECURITY command or on the APPL definition statement.
MACTYPE NOT VALID
The operator entered a MODIFY SECURITY command with a MACTYPE value that is not valid with the most recent specification of MACLNTH. The MACLNTH value might have been specified on a previous MODIFY SECURITY command or on the APPL definition statement.
MODEL LU NOT VALID
The operator entered a DISPLAY LUGROUPS command for nodename. Model LU nodename was not found in the LUGROUP specified on the GROUP operand of the DISPLAY LUGROUPS command.
MODULE LOAD FAILED
Attempt to load XCF modules fails.
MUST BE APPLICATION
The operator entered a MODIFY ENCR command or MODIFY SECURITY command for nodename for one of the following purposes:
  • To set the encryption level to CONDITIONAL
  • To set the values of MACLNTH or MACTYPE.

MACLNTH, MACTYPE, and the CONDITIONAL encryption level are valid only if nodename is an application program.

MUST BE MORE SECURE
The operator entered a MODIFY ENCR command or MODIFY SECURITY command for nodename to lower (make less secure) the level of cryptographic session for the logical unit or application program indicated by nodename. The level of cryptographic session for a logical unit or application program can only be raised (made more secure). For example, if you have defined an LU as selective, you cannot modify it to optional. You can modify it to required.
NODE KEY UNDEFINED
The operator entered a MODIFY ENCR command or a MODIFY SECURITY command for nodename, and the node nodename does not have a properly defined cryptographic key in the cryptographic key data set.
NOT SUPPORTED
A MODIFY TRACE command or TRACE start option was specified with the value TYPE=QDIOSYNC. When the OSA-Express2 or later adapter was contacted, it was discovered that it does not support the QDIOSYNC function.
PROGRAM NOT ACTIVE
The Cryptographic Facility is not available to process a MODIFY ENCR command.
RESOURCE NOT VALID
The operator entered a MODIFY SECURITY command with the CKEY operand for nodename, but nodename is not a device type LU.
RESOURCES NOT FOUND
The operator entered a VARY ACQ or a VARY REL command, but it had no effect on the NCP.

Either all the resources were acquired or released already, or the OWNER specified on the command did not match any of the owner names specified on the NCP's resources. Two different networks cannot share the same native resources.

RTP PU NOT VALID
A VARY ACT command for an RTP PU is issued. This is a dynamic PU and activates automatically if RTP is supported. A VARY ACT of a RTP PU is invalid.
SECURITY DATA ERROR
VTAM detected a mismatch of the encrypted security data fields during the XID exchange. This mismatch may be caused by one of the following:
  • An unauthorized subarea dial physical unit attempted to establish a connection over a switched line.
  • The PRTCT operand was absent.
  • The correct password was not coded for both the caller and receiver.
  • One of the subarea nodes is of a level that does not support call security verification.
SECURITY ERROR
A security error occurred while VTAM was processing the command command.
STORAGE SHORTAGE
The operator entered a MODIFY ENCR command for nodename and the VTAM address space has insufficient storage.
SUPPORT UNAVAILABLE
The security manager is not available or the resource class APPCLU is not active.
SYSPLEX JOIN FAILED
VTAM is attempting to join the sysplex, but a nonzero return code is sent from MVS™.
SYSPLEX UNAVAILABLE
VTAM is attempting to join the sysplex, but the sysplex is not active.
VTAM ABEND
One of the following occurred:
  • VTAM abended while processing a MODIFY PROFILES command.
  • VTAM abended while processing a MODIFY ENCR command for nodename. The error may be due to the improper cleanup of the cryptographic facility (that is, the operator cancelled the cryptographic facility via the CANCEL command).
XCF BUILD FAILED
A VARY ACT command fails for a dynamic local SNA major node.
XCF PU NOT FOUND
A D TRL,XCFCP=cp_name command was issued for nodename. The nodename is the CP name specified in the display command. The associated dynamic PU for that CP was not located.
XCF TRLE NOT FOUND
One of the following occurred:
  • A D,TRL,XCFCP=cpname command was issued for nodename. The nodename is the CP name specified in the display command. The associated dynamic TRLE for that CP was not located.
  • A V,NET,ACT,ID=ISTLSXCF command was issued. An XCF connection is in the process of being deactivated and an activation request is received. The dynamic TRLE which is required for activation does not exist.

System action

The command is not completed. Processing continues.
CDRSC IS DYNAMIC or CDRSC NOT ALLOCATED
LU nodename remains known to VTAM in an inactive state with active sessions.
FUNCTION NOT OPERATIONAL, NOT SUPPORTED, or ARM REJECTED
The command is not executed.
INSTALL PROGRAM
Install Cryptographic Facility.
SECURITY DATA ERROR
VTAM terminates the switched connection and deactivates the PU.
SECURITY ERROR or SUPPORT UNAVAILABLE
VTAM does not refresh the profiles and continues to use the profiles that are in storage.

Operator response

The reason determines the response:
ALSNAME NOT GIVEN
Enter a DISPLAY ID command for nodename to determine the correct adjacent link station, and reenter the command.
ALSNAME NOT VALID
Enter a DISPLAY ID command for nodename to determine the correct adjacent link station, and reenter the command.
The state (active or inactive) of the PU with which the independent LU is associated must be as follows:
  • Active if it has been dynamically reconfigured in the NCP
  • Active if it is on an NCP switched line
  • Active or inactive if it is on an NCP nonswitched line.
CDRSC IS DYNAMIC or CDRSC NOT ALLOCATED
Activate a CDRSC major node that defines a CDRSC with nodename.
DEACTIVATE PENDING
Wait until all subordinate nodes have completed deactivation and try the command again.
ISTLSXCF NOT ACTIVE
Enter a VARY,ACT,ID=ISTLSXCF to activate ISTLSXCF.
MACLNTH NOT VALID
Try the command again with a valid value for MACLNTH.
MACTYPE NOT VALID
Try the command again with a valid value for MACTYPE.
MODEL LU NOT VALID
Check that nodename is correct and try the command again. If problems persist, save the system log for problem determination.
NOT SUPPORTED
Issue the DISPLAY NET,TRL,TRLE=trlename command to display the active OSA-Express2 or later TRLE. Look for message IST1716I or message IST2263I in the response. The OSA CODE LEVEL field is at the end of these messages. Record this value for the system programmer.
PROGRAM NOT ACTIVE
Make sure the Cryptographic Facility is installed and operational.
RESOURCE NOT VALID
Check that nodename is correct and try the command again. If problems persist, save the system log for problem determination.
RESOURCES NOT FOUND
Verify that all of the NCP resources have been acquired or released or that the OWNER specified on the command matches the owner name specified on the resources to be acted upon.
SECURITY DATA ERROR
Monitor the console for further occurrences of this message. If VTAM continues to issue this message, use the VARY ANS command to take the line out of answer mode.
SECURITY ERROR
Try the command again. If VTAM continues to issue this message, contact the security administrator.
STORAGE SHORTAGE
If VTAM continues to issue this message, enter the DISPLAY BFRUSE command. Issue the DISPLAY STORUSE command to display storage usage for storage pools. Save the system log and request a dump for problem determination.
VTAM ABEND
Save the system log and dump for problem determination.

If the error was due to the improper cleanup of the cryptographic facility, enter the STOP command to stop the cryptographic facility, and save the system log for problem determination.

XCF PU NOT FOUND
Check the CP name specified on the parameter XCFCP to ensure it is correct and try the command again. Issue a DISPLAY TRL,CONTROL=XCF to determine whether any XCF TRLEs exist. Issue a DISPLAY ID=ISTLSXCF to determine whether an associated dynamic PU exists for the connection.
XCF TRLE NOT FOUND
Check the CP name specified on the parameter XCFCP to ensure it is correct and try the command again. Issue a DISPLAY TRL,CONTROL=XCF to determine whether any XCF TRLEs exist.
All other reasons
Save the system log for problem determination.

System programmer response

The reason determines the response:
ARM REJECTED
Perform the following traces to help you determine the cause of the rejection:
  • A CCW trace of the TRLE read and write control channels taken at the time of the first attempt to arm the adapter. This trace will show the Arm request being written and the Arm reply being read. Use a CCW trace data length of 256 bytes.
  • A CTRACE using the VTAM and VTAMDATA options.
  • A VTAM internal trace using the CIA and CIO options.
CDRSC IS DYNAMIC
Reenter the TRACE command with a resource that is not a dynamic cross-domain resource. You cannot trace a dynamic cross-domain resource.
CDRSC NOT ALLOCATED
Take VTAM down, and restart it so that it supports dynamic CDRSCs.
EXIT IS NOT FOUND
Make sure the VTAM installation-wide exit that could not be found has been installed on your system.
INSTALL EXIT REJECT
GENKEY failed with RETURN CODE 16 from the common cryptographic architecture product (CCA) or the IBM® Cryptographic Unit Support product (CUSP).

For further information, see the documentation for the cryptographic facility that you are using.

MODEL LU NOT VALID
Check the definition of nodename to ensure that it is correct.
MUST BE APPLICATION
Make sure nodename is the correct node name. If nodename is the correct name, see z/OS Communications Server: SNA Operation for more information on valid encryption levels. Otherwise, reenter the MODIFY ENCR command with the correct value for nodename.
MUST BE MORE SECURE
If you want to lower the cryptographic session level of a node, you must redefine the system definition cryptographic option in SYS1.VTAMLST and reactivate the major node that contains nodename.
NODE KEY UNDEFINED
Define the cryptographic key for node nodename in the cryptographic key data set. For information about defining cryptographic keys, see the z/OS Cryptographic Services ICSF System Programmer's Guide and the z/OS Communications Server: SNA Network Implementation Guide.
NOT SUPPORTED
The OSA code level determined by the operator indicates the OSA processor code level of the OSA-Express2 or later adapter. That value will show that the OSA-Express2 or later processor code level is insufficient. You must upgrade to a level that supports QDIOSYNC to use the function.
SECURITY DATA ERROR
Verify that all nodes involved in the dial process are at a level that supports call security verification. The passwords used to verify the identity of the caller and the receiver must match. See the PRTCT keyword on the PU statement in the switched major node definition.
STORAGE SHORTAGE
If this error occurs often, review the VTAM storage allocation. Increase storage as required.
SYSPLEX JOIN FAILED
Trace the return code from MVS. Verify that the sysplex environment exists and restart VTAM.
VTAM ABEND
See the z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures for information on the abend procedure. If you cannot determine the cause of the problem from the output provided or need additional assistance, contact the IBM software support center.

If the error was due to the improper cleanup of the cryptographic facility, start the cryptographic facility if it is not already started.

XCF BUILD FAILED
Restart VTAM with full XCF support.
XCF PU NOT FOUND
Verify that XCF support is active for this VTAM.
XCF TRLE NOT FOUND
Verify that XCF support is active for this VTAM.

For all other reasons, no further action is recommended.

Routing code

2

Descriptor code

5