Explanation
This message is part of a message group. The first
message in the group is IST663I. See the explanation of that message
for a description of the entire message group.
This message
is the first of a subgroup of messages in the IST663I group of messages.
A complete description of the message subgroup follows.
IST1015I APPLICATION SUPPLIED parameter_name = parameter_value
[IST1028I parameter_value]
This message subgroup
is issued only to the operator of the host of the secondary logical
unit.
parameter_name is the name of the
parameter displayed in the message subgroup, and is one of the following:
- CPNAME
- parameter_value displays the control point
(CP) name of the type 2.1 peripheral node supplied by the application
program for the switched connection.
- GROUP NAME
- parameter_value displays the name of a GROUP
definition statement in the NCP or channel attachment major node that
defines a group of SDLC switched links.
- DIAL NUMBER
- parameter_value displays the line number supplied
by the application program for the switched connection. If parameter_value contains
unprintable characters, the message will appear as follows:
IST1015I APPLICATION SUPPLIED DIAL NUMBER=X'parameter_value'
If
the message contains any unprintable characters, the dial number is
preceded by an "X". If the message contains only printable characters,
the dial number is not preceded by an "X".
- DLCADDR SUBFIELD
- parameter_value displays the DLCADDR subfield
supplied by the application program for the switched connection. If parameter_value contains
unprintable characters, the message will appear as follows:
IST1015I APPLICATION SUPPLIED DLCADDR SUBFIELD=yy,X'parameter_value'
If
the message contains any unprintable characters, the DLCADDR subfield
is preceded by an "X". If the message contains only printable
characters, the DLCADDR subfield is not preceded by an "X".
yy is
the subfield ID.
- DIRECT CALL LINE
- parameter_value displays the name of the line
supplied by the application program for the switched connection.
- IDBLK/IDNUM
- parameter_value displays the identification
block (IDBLK) and identification number (IDNUM) supplied by the application
program for the switched connection. IDBLK identifies the device type
and IDNUM identifies the specific device or connection for the switched
connection.
For IDBLK/IDNUM,
parameter_value is
64 characters long; there are no spaces between the values of IDBLK
and IDNUM. This field is always displayed in hex. VTAM® displays the first portion of
parameter_value in
message IST1015I and the remainder in message IST1028I. The message
subgroup will appear as follows:
IST1015I APPLICATION SUPPLIED IDBLK/IDNUM=X'parameter_value
IST1028I parameter_value'
See the z/OS Communications Server: SNA Resource Definition
Reference for more information on the IDBLK, IDNUM,
and CPNAME operands for switched major nodes.
System action
The session initiation attempt fails.
Operator response
Save the system log for problem determination.
System programmer response
Use the information in messages IST663I,
IST664I, and IST889I to determine the cause of the error. Possibilities
include dial numbers not in the correct form or an XID failure. This
is not necessarily a system programmer error. If it is not, notify
the application programmer.
Routing code
Descriptor code