z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


FNDENDEL

z/OS Communications Server: SNA Diagnosis Vol 1, Techniques and Procedures
GC27-3667-00

Use FNDENDEL to help diagnose problems with adjacent end nodes. For a particular resource, FNDENDEL provides the associated ENDEL control block.

FNDENDEL has no required operands. If you do not enter a resource name, all ENDEL control blocks are formatted.

Operands

Network ID
The network ID should be 1–8 alphanumeric characters. If it contains fewer than 8 characters, the leftmost characters are compared.
Resource name
The resource name should be 1–8 alphanumeric characters. If it contains fewer than 8 characters, the leftmost characters are compared.

Use the following syntax as an alternative to the panel interface.

Syntax

Read syntax diagramSkip visual syntax diagram
>>-FNDENDEL--+-----------+--+-------------+--------------------><
             '-| NETID |-'  '-| RESNAME |-'   

NETID

|-- --NETID--(--netid--)----------------------------------------|

RESNAME

|-- --RESNAME--(--resource_name--)------------------------------|

Sample output

FNDENDEL RESNAME(A04P208A)
 
                         FNDENDEL Analysis
 
 ENDEL: 06A41020
    +0000  C5D5C4D3  00000000  06A41048  000DD5C5  | ENDL.....u....NE |
    +0010  E3C14BC1  F0F4D7F2  F0F8C140  40404000  | TA.A04P208A    . |
 