Some problems that occur in the system logger can be fixed with
relatively simple adjustments to data set sizes or logger policy parameters.
The following is a list of common problems that can be remedied by
the user:
- If log stream data is missing or inaccessible, or new log stream
offload data sets are being allocated before the old ones are filled,
it may be that the Virtual Storage Access Method (VSAM) SHAREOPTIONS
(3,3) was not specified when the data set was allocated (the default
for SHAREOPTIONS is 1,3).
- If log stream data is deleted unexpectedly, or is retained too
long, check AUTODELETE and RETPD in the LOGR policy to verify that
the correct values have been specified.
- Offload problems may be caused by improper sizing of the log stream
offload data sets (LS_SIZE). Small data sets may result in too many
offload data sets, which can cause directory problems.
- Incorrect sizing of the staging data set (STG_SIZE) may cause
offloads to occur too frequently.
- Message IXG251I with reason code 805 can mean that IXGLOGR is
not marked as TRUSTED to the security product, preventing data sets
from being allocated. If this is true, update the attribute and stop
and restart the IXGLOGR address space to have the
new authority take affect. See Restarting the system logger address space for
information on getting the IXGLOGR address space restarted.
If this is not the cause of the problem (IXGLOGR is marked as
TRUSTED), examine associated syslog messages for a possible SMS or
catalog problem.
- Message IXG002E with return code 8 and reason code 823 can indicate
that the LSR, LSTRR or DSEXTENT values in the logger policy are not
sufficient.
- Incorrect sizing of a list structure or by having too many log
streams in a list structure can cause errors. You might be able to
avoid this problem by using the System z® Coupling Facility Structure Sizer Tool (CFSizer). The CFSizer
simplifies the task of estimating the amount of storage required by
the coupling facility structures used in your installation. The CFSizer
asks questions about your existing configuration, and then use the
answers you give to build customized jobs that you can run to create
various structures as well as the LOGR couple data set, and OPERLOG
and LOGREC log streams. See the http://www.ibm.com/systems/support/z/cfsizer/.
- Using IDCAMS REPRO to copy log stream offload data sets can result
in errors indicated by messages IDC3302I, IDC3350I such as the following:
REPRO INFILE(SYS00014) -
OUTFILE(SYS00015)
IDC3302I ACTION ERROR ON MTSYSL.CICSAAU3.USAUAAU3.DFHLOG.A0000010
IDC3350I 10014,15173874,00000000B000,D,AXR000,USZCZT0T,STEP1,6
6D7,DA,SYS00014,A6- OP,INCORR. LENGTH ,00000020000B0C,VSAM
IDC3302I ACTION ERROR ON MTSYSL.CICSAAU3.USAUAAU3.A0010074.T5173829
IDC3351I ** VSAM I/O RETURN CODE IS 28 - RPLFDBWD = X'2908001C'
IDC31467I MAXIMUM ERROR LIMIT REACHED.
IDC0005I NUMBER OF RECORDS PROCESSED WAS 36
IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
If you receive this error, see the topic Managing logger log stream data sets for
the subtopic on "Copying log stream offload data sets" in z/OS MVS Setting Up a Sysplex.