z/OS MVS Programming: Sysplex Services Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Responding to the XES Recommended Action Event

z/OS MVS Programming: Sysplex Services Guide
SA23-1400-00

The action that XES recommends to those connectors who have lost connectivity to a coupling facility structure is that the connection should disconnect from the structure. The recommendation is based on the percentage scope of lost connectivity calculated from the weights specified in the SFM policy. The percentage value in EEPLXESRECOMMENDACTIONPCTLOSSCONN indicates the percentage scope of lost connectivity calculated from the weights specified in the SFM policy, as seen by the system receiving the event. This percentage value is valid only when EEPLXESRECOMMENDACTIONPOLICY is equal to B'1'.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014