z/OS MVS Programming: Sysplex Services Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Parameter List Contents

z/OS MVS Programming: Sysplex Services Guide
SA23-1400-00

The parameter list that XCF passes to the status user routine is mapped by the IXCYSEPL mapping macro and pointed to by GPR 1. The parameter list is addressable from the primary address space in which the status user routine runs, and includes the following information:
  • Member data value provided by the IXCJOIN macro (MEMDATA parameter).
  • Address of the member's status field.
  • Whether XCF was checking for status update missing or status update resumed.
  • The member's token.

See SEPL in z/OS® MVS™ Data Areas in the z/OS Internet library for complete field names and lengths, offsets, and descriptions of the fields mapped by the IXCYSEPL mapping macro.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014