z/OS Network File System Guide and Reference
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


GFSA335E (procname)

z/OS Network File System Guide and Reference
SC23-6883-00

GFSA335E (procname)
MOUNT HANDLE DATA SET CANNOT BE WRITTEN, EXPECTING LEN d_digits1 REAL LEN d_digits2, VSAM R15(DEC) d_digits3 REASON CODE(DEC) d_digits4 LAST OP(DEC) d_digits5.

Explanation

The NFS server attempted to write a mount record to the mount handle database but could not do so. The length of the mount record is d_digits1 bytes, but only d_digits2 bytes were written. The failing information in writing the virtual storage access method (VSAM ) key-sequenced data set (KSDS) mount handle database is the decimal return code d_digits3, the decimal error code or reason code d_digits4, and the code for the last operation d_digits5.

In the message text:

procname
The name of the start procedure.

System action

System processing continues but in a degraded mode. Additional mounts or unmounts might fail in writing the record to the mount handle data set.

Operator response

Contact the system programmer.

System programmer response

The mount handle data sets have probably become unusable and need to be either cleared or restored to some previous level, and then the server has to be restarted. The information for the mount point was not saved in the mount handle data set. Clients might have to unmount and mount these mounted directories when the server is restarted.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014