GFSA824W (procname)
NETWORK FILE SYSTEM CLIENT ipaddr (clientname) DID NOT SEND COMPLETE RECORDS FOR OFFSET (offset) FOR DATA SET dsname WITHIN seconds SECONDS.

Explanation

During MVS z/OS conventional data set timeout for the data set dsname in TEXT mode, the NFS server detected incomplete records sent by the NFS client ipaddr(clientname) that were not completely processed in the required time (seconds) of the timeout value that was extended.

In the message text:

procname
The name of the start procedure.
ipaddr
The client IP address
clientname
Client name
offset
Offset into record
dsname
Name of data set
seconds
Time in seconds

System action

NFS server continues processing without closing the detected data set. NFS server will wait for an extended period for the NFS client to send the needed data to complete the records.

Operator response

Contact the end user.

User response

Check the network and end-user application on the client side. It is possible that the client terminated or an application is hung or has terminated. Restart the application or re-boot the client workstation to continue processing the data set.