0 |
(0) |
Successful completion without error. |
4 |
(4) |
A warning condition occurred for
one of the following reasons: - Duplicate names that IBM® defined
caused one or more warning conditions.
- An expected output DD statement (OUTDDn)
was not found. IRRUT400 continued processing. Note that if you intentionally
did not specify an output DD statement, IRRUT400 continues processing
to identify inconsistencies in the RACF® database,
and you can ignore this warning.
|
8 |
(8) |
One or more error conditions occurred
because of one of the following conditions: - Duplicate names that IBM did
not define
- A defective tape-volume set
|
C |
(12) |
One or more severe error conditions
resulted from an error on an output data set. |
10 |
(16) |
A terminating error condition occurred
for one of the following reasons: - A recovery environment could not be established.
- The SYSPRINT file could not be opened.
- An error was found in a parameter specification.
- A range table was requested but could not be loaded.
- An error was detected in the specified range table.
- An error occurred on an input data set.
- LOCKINPUT or UNLOCKINPUT was specified when the system was running
in read-only mode.
- An error related to the coupling facility occurred during LOCKINPUT
or UNLOCKINPUT processing.
- All input data sets contained valid ICBs, but none contained profiles.
- An INDD statement and an OUTDD statement point to the same data
set
- An OUTDD statement specifies an active RACF data set on this system
|
20 |
(32) |
RACF is
not enabled. As a result, the utility was not run and the RACF database was not formatted.
For information on enabling RACF,
see Enabling and disabling RACF. See z/OS MVS Product Management
for information on enabling products. After you make the updates required
to enable RACF, you must re-IPL
in order for the updates to take effect.
|