- 1
- /*SIGNON
- 16
- REMOTEnn | RMTnnnn
- 25
- password1
- 35
- newpass
- 73
- password2
- RMTnnnn|REMOTEnn
- Defines the RJE workstation requesting signon.
Note: The
long form (REMOTEnn) is only valid for RJE workstations 1 through
99.
- password1
- Defines the password established at initialization or changed
by the operator for that line. If the line has a password, then password1
is required.
To establish password1, specify the LINE(nnnn) JES2
initialization statement. You can change this password through the
$T LINE(nnnn) command.
- newpass
- Specifies the password used by the Resource Access Control Facility
(RACF®) to change the password of this remote. If RACF is not active, you cannot change the remote's password in this
way. See Providing security for JES2 for information about
using RACF to control RJE workstations.
If you are
using RACF to control the RJE workstations, you must
specify newpass the first time this remote issues a logon or signon.
Otherwise, RACF will reject the access attempt. See Providing security for JES2 for information about defining an RJE
workstation to RACF.
- Password2
- Defines the password maintained by RACF unless
you use JES2 remote password control. If you use JES2 remote password
control, JES2 establishes this password through a RMT(nnnn) initialization
statement, or through a $ADD RMT(nnnn) command or a $T RMT(nnnn) command.
If the terminal has a password, then password2 is required to ensure
that the RJE workstation signing on is a valid workstation.
|