Sense code 1008

Invalid FM header: The FM header was not understood or translatable by the receiver, or an FM header was expected but not present. For LU 6.2, this sense code is sent in FMH-7 or UNBIND.

Table 1 shows the usage of the allowed values by LU type.

Table 1. Usage of hexadecimal 1008 sense code specific information by LU type
Range LU 1 LU 4 LU 6.1 LU 6.2
0801–0824 X X    
0825 X      
0826–082A X X    
2001–200D X X    
200E X X X  
200F–201C X X    
201D       X
4001–400E X X    
6000       X
6001,6004     X  
6005     X X
6006–6008     X  
6009     X X
600A     X  
600B     X X
600C–6010     X  
6011–6034       X
6040     X X
6041       X
6046       X
6047       X
6048       X
C000–C003     X  

Bytes 2 and 3 following the sense code contain sense code specific information.

0000
No specific code applies.
0801
The function code parameters are not valid.
0803
The forms functions cannot be performed.
0805
The copy function cannot be performed.
0806
Compaction table outside the supported set: The number of master characters is not within the valid range.
0807
The PDIR (peripheral data information record) identifier is not valid.
0808
The printer train function cannot be performed.
0809
The FCB (forms control block) load function cannot be performed.
080A
The FCB (forms control block) load function is not supported.
080B
The compaction table name is not valid.
080C
The ACCESS is not valid.
080D
The RECLEN is not valid.
080E
The NUMRECS is not valid.
080F
The data set is in use.
0810
The data set cannot be found.
0811
The password is not valid.
0812
The function is not allowed for the destination or for the data set.
0813
The record is too long.
0814
The data set is full.
0815
The RECID is not valid.
0817
The VOLID format is not valid.
0818
The maximum number of logical records per chain is exceeded.
0819
The data set exists.
081A
No space is available.
081B
The VOLID is not valid.
081C
The DSACCESS is not valid.
081D
The RECTYPE is not valid or the data set cannot be found.
081E
The resolution space is insufficient.
081F
The key technique is not valid.
0820
The key displacement is not valid.
0821
The key is not valid.
0822
There is an not valid N (number of records).
0823
The KEYIND is not valid.
0824
The SERID is not valid.
0825
Disk error: An error was detected while reading from, or writing on, the disk.
0826
The RECID format is not valid.
0827
The password has not been supplied.
0828
The record ID has not been supplied.
0829
The volume ID has not been supplied.
082A
The PGMNAME is not valid.
2001
The destination (active) is not valid.
2002
The destination (inactive) is not valid.
2003
The destination (suspended) is not valid.
2004
The suspend-resume sequence is not valid.
2005
There has been an interruption level violation.
2006
The resume properties are not valid.
2007
The destination is not available.
2008
The end sequence is not valid.
2009
The FM header length is not valid.
200A
Field setting is not valid: The reserved field is set to one or the setting is not defined.
200B
Destination is not valid: The destination does not exist.
200C
The ERCL is not valid.
200D
The data stream profile (DST) is not valid.
200E
Concatenation indicator is not valid: The concatenation indicator is on, but concatenation is not allowed.
200F
FM data is not allowed for the header.
2010
The FM header set specified in the BIND has been violated.
2014
The FM header was not sent concatenated.
2019
The stack reference indicator (SRI) is not valid.
201A
The CMI modification could not be accepted.
201B
The CPI modification could not be accepted.
201C
The ECRL modification could not be accepted.
201D
FM header and associated data mismatch: The FM header indicated that associated data would or would not follow (for example, FM Header 7 followed by log data, or FM Header 5 followed by program-initialization parameters), but this indication was in error; or a previously received RU [for example, -RSP(X'0846')] implied that an FM header would follow, but none was received.
4001
FM header type for this LU is not valid: The type of the FM header is other than five, seven, or 12.
4002
The FMH code is not valid.
4003
Compression is not supported.
4004
Compaction is not supported.
4005
Basic exchange is not supported.
4006
Only basic exchange is supported.
4007
The medium is not supported.
4008
There has been a code selection compression violation.
4009
FMHC is not supported.
400A
Demand select is not supported.
400B
DSNAME is not supported.
400C
The media subaddress field is not valid.
400D
There are insufficient resources to perform the requested function.
400E
Data stream profile (DSP) select is not supported.
6000
FM header length not correct: The value in the FM header length field differs from the sum of the lengths of the subfields of the FM header.
6001
The deblocking algorithm (DBA) is not valid.
6004
The queue name length is not valid.
6005
Access security information length field not correct: The value in the access security information length field differs from the sum of the lengths of the access security information subfields.
6006
The data stream profile (DSP) is not valid.
6007
The FMH-7 is not preceded by a negative response carrying sense code X'0846'.
6008
The attach access code is not valid.
6009
Parameter length is not valid: The field that specifies the length of fixed-length parameters has a setting that is not valid.
600A
This is not the first FMH-5, the interchange unit type is not the same as the old, and the interchange unit end indicator is off.
600B
Unrecognized FM header command code: The partner LU received an FM header command code that it does not recognize. For LU 6.2, this sense data is sent only in FMH-7.
600C
A null sequence field is required.
600D
User-to-user program transition is not allowed.
600E
User to non-SNA defined program transition is not allowed.
600F
The FMH-5 reset attached program (RAP) was not sent properly.
6010
The FMH-5 reset attached program (RAP) was sent with an inactive attach register.
6011
Logical unit of work (LUW) not valid: The LUW length field (in a compare states GDS variable or an FMH-5) is incorrect, or the length field is not valid, or a LUW ID is not present but is required by the setting of the synchronization level field.
6021
Transaction program name not recognized: The FMH-5 attach command specifies a transaction program name that the receiver does not recognize. This sense data is sent only in FMH-7.
6031
PIP not allowed: The FMH-5 attach command specifies that program initialization parameter (PIP) data is present, but the receiver does not support PIP data for the specified transaction program. This sense data is sent only in FMH-7.
6032
PIP not specified correctly: The FMH-5 attach command specifies a transaction program name that requires program initialization parameter (PIP) data, and either the FMH-5 specifies PIP data is not present or the number of PIP subfields present does not agree with the number required for the program. This sense data is sent only in FMH-7.
6034
Conversation type mismatch: The FMH-5 attach command specifies a conversation type that the receiver does not support for the specified transaction program. This sense data is sent only in FMH-7.
6040
Attach parameter is not valid: A parameter in the FMH-5 attach command conflicts with the statement of LU capability previously provided in the BIND negotiation.
6041
Synchronization level not supported: The FMH-5 attach command specifies a synchronization level that the receiver does not support for the specified transaction program. This sense data is sent only in FMH-7.
6042
Reconnection not supported: The FMH-5 attach command specifies reconnection support, but the receiver does not support reconnection for the specified transaction program. This sense data is sent only in FMH-7.
6043
Unable to reconnect transaction program—no retry: The FMH-5 reconnect command specifies the conversation correlator of a transaction program to which the receiver cannot reconnect. The condition is not temporary. This sense data is sent only in FMH-7.
6044
Unable to reconnect transaction program—retry allowed: The FMH-5 reconnect command specifies the conversation correlator of a transaction program to which the receiver cannot reconnect. The condition is temporary. This sense data is sent only in FMH-7.
6046
An SNA/DS transaction program is unable to allocate a conversation with an SNA/DS partner.
6047
An SNA/DS transaction program in conversation with an adjacent SNA/DS transaction program has detected from LU 6.2 PS a return code of resource_failure.
6048
An SNA/DS transaction program in conversation with an adjacent SNA/DS transaction program has detected from LU 6.2 PS a return code of deallocate type (abend).
6050
For the receiver, one of the following conditions exists:
  • Extended security bit is on and GDS variable X'12F6' does not immediately follow the attach FMH-5 and PIP data.
  • Extended security bit is off and GDS variable X'12F6' follows the attach FMH-5.
For the sender, one of the following conditions exist:
  • The partner responded to the attach with any data other than an FMH7 or an authenticator reply (GDS id X'12F8').
  • The authenticator reply subfield (X'FF85') is absent.
  • A subfield occurs more than once.
6051
One of the following conditions exist:
  • The length of the GDS variable is incorrect. The length must be greater than zero and must equal to (length_field_value -2).
  • An unidentified subfield is present in the GDS variable.
  • The total length of a subfield is not equal to the value in its length field minus 2.
6053
The length of the GDS variable is incorrect. It is the responsibility of the application to ensure that the GDS variable length is correct. For the sender, the length must be greater than or equal to two and must equal the value in the length field.
6054
For the receiver, the extended security bit is on and either old FMH-5 security bits are on or the old access security information fields are present. For the sender, the authenticator reply fails the checks applied by the security manager. (Purge ID from Signed On To list.)
6056
The partner responded to the attach with any data other than an FMH7 or an authentication token (GDS variable X'12F6').
6057
The authentication token GDS requested that additional token exchanges be handled via the distributed authentication service TP. However, the FMH5 did not contain a valid conversation correlator.
C000
The header is not supported.
C001
The header length is not valid.
C002
There has been a logical message services block-level error.
C003
There is a version ID mismatch.