Sense code 08A0

Session Reset: An LU or PU is resetting an LU-LU session.

Bytes 2 and 3 following the sense code contain sense code-specific information.
0000
No specific code applies.
0001
The LU is sending an UNBIND with a reason code of X'0A' (SSCP gone); the identified LU-LU session had to be deactivated because of a forced deactivation of the associated SSCP-PU or SSCP-LU session, for example, because of a DACTPU, DACTLU, or DISCONTACT.
0002
The LU or SCM is sending UNBIND with a reason code of X'0F' (cleanup).
0003
A gateway node is cleaning up the session because a gateway SSCP has directed the gateway node (via NOTIFY) to deactivate the session, for example, a session setup error or session takedown failure has occurred. The gateway node will send UNBIND with a reason code of X'11' (gateway node cleanup).
0004
Reversed FRSN values: The value in the last FRSN Sent field is greater than the value in the current FRSN field in a received TDU GDS variable (no retry). The CP will send an UNBIND with a reason code of X'0F' (Cleanup).
0005
TDU sent out of order: The value in the last FRSN sent field of the current TDU GDS variable is less than the value of the current FRSN field in the TDU GDS variable that immediately preceded it, or is greater than it and the receiver cannot store the out-of-sequence value (no retry). The CP will send an UNBIND with a reason code of X'0F' (Cleanup).

VTAM® hint: If this sense code is issued in the IST1097I message group (CP-CP sessions have been deactivated), it is likely that the topology database update (TDU) flowing between the two nodes has been lost. This is probably due to a storage depletion condition on either the sending or receiving end of the TDU flow.

If the CP-CP sessions do not come back up automatically, reactivate the CP-CP session by issuing VARY ACT,ID=partner_cpname,IDTYPE=CP. If VTAM is experiencing temporary storage allocation problems, you might want to wait for the condition to clear before attempting to restart the session.

When the CP-CP session is restarted, TDUs will be exchanged so that the missing information in the lost flow will be recovered.

0006
This sense code can be displayed in a VTAM message but is set by another product.
VTAM hint: If this sense code is issued in the IST1097I message group (CP-CP sessions have been deactivated), it is likely that CM/2 is failing the CP-CP session because the flow reduction sequence number (FRSN) in the topology database update (TDU) sent by VTAM is higher than expected by CM/2. Perform the following steps:
  1. Delete the entry for the adjacent node from the topology database by issuing the MODIFY TOPO command: F TOPO,ID=cpname,TYPE=FORCE. All links between VTAM and the partner node must be inactive before issuing the MODIFY TOPO command.
  2. After deleting the node, reactivate the CP-CP session.
0007
DLUS-DLUR session deactivation (disruptive): LU-LU sessions for DLUR-supported dependent LUs should be reset
0008
DLUS-DLUR session deactivation (non-disruptive): LU-LU sessions for DLUR-supported dependent LUs should not be reset
0009
DLUS-DLUR session deactivation (non-disruptive): protocol violation detected (LU-LU sessions for DLUR-supported dependent LUs should not be reset)
000A
DLUS-DLUR session deactivation (non-disruptive): DLUR should wait for DLUS reactivation of DLUS-DLUR session (LU-LU sessions for DLUR-supported dependent LUs should not be reset)
000C
The DLUS node has received from the DLUR node a FID2 Encapsulation (X'1500') GDS variable with a PIU length field of zero.