Sense code 086B

Subfield value not valid: A value in a subfield within an MS major vector is not valid for the receiver.

nnmm
Byte 2 following the sense code contains the subvector key (nn) of the subvector containing the subfield with the value that was not valid, and byte 3 contains the subfield key (mm) of the subfield with the invalid value.
Note: See sense code X'0870' for the case in which the invalid value occurs in an unformatted subvector, that is, one not containing subfields with keys and lengths, or in the unformatted portion of a partially formatted subvector.
6991
Dial information error
ATM
ATM dial information does not indicate ATMSVC or SHARE/EXCLUSIVE.
VTAM® hint: A possible cause of this error is that the values ATMSVC or SHARE or EXCLUSIVE might be missing or could be specified incorrectly on the DLCADDR operand (subfield 1) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)

See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH statement in the switched major node.

EE
A mismatch of IP address families has been detected. See message IST1891I for specific information about the error.
6997
ATM traffic description is not valid.
VTAM hint: A possible cause of this error is that the best effort indicator, cell rates, and traffic management options might be missing or could be specified incorrectly on the DLCADDR operand (subfield 7) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)

See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.

6998
ATM quality of service (QoS) class is not valid.
VTAM hint: A possible cause of this error is that the quality of service (QoS) class might be missing or could be specified incorrectly on the DLCADDR operand (subfield 8) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)

See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.

6999
ATM transit network selection (TNS) identifier is not a valid length.
VTAM hint: A possible cause of this error is that the carrier identification code might be missing or could be specified incorrectly on the DLCADDR operand (subfield 9) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)

See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.

69A5
ATM addresses are not a valid length or type.
VTAM hint: A possible cause of this error is that the ATM address or addresses might be missing or could be specified incorrectly on the DLCADDR operand (subfield 21) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)

See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.

69C3
ATM bearer capabilities are not specified or are specified incorrectly.
VTAM hint: A possible cause of this error is that the ATM bearer capabilities are not specified or are specified incorrectly on the DLCADDR operand (subfield 51) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)
See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.
69CD
ATM adaptation layer is not specified or is specified incorrectly.
VTAM hint: A possible cause of this error is that the ATM adaptation layer is not specified or is specified incorrectly on the DLCADDR operand (subfield 61) on the following definition statements in the following major nodes:
  • GROUP definition statement in the XCA major node (TGs to connection networks)
  • PATH definition statement in the switched major node (TGs over SVCs)
See z/OS Communications Server: SNA Resource Definition Reference for information about how to code the DLCADDR operand on the GROUP definition statement in the XCA major node and for information about how to code the DLCADDR operand on the PATH definition statement in the switched major node.