Message type

Figure 1. Contents of the message type diagnostic code
Diagram that shows the format of the message type diagnostic code.

Table 1 describes the contents of the message type diagnostic code.

Table 1. Message type
Byte Description
7

Call Establishment Messages:

X'02'
CALL PROCEEDING
X'07'
CONNECT
X'0F'
CONNECT ACKNOWLEDGE
X'05'
SETUP

Call Clearing Messages:

X'4D'
RELEASE
X'5A'
RELEASE COMPLETE
X'46'
RESTART
X'4E'
RESTART ACKNOWLEDGE

Point-to-Multipoint Messages:

X'80'
ADD PARTY
X'81'
ADD PARTY ACKNOWLEDGE
X'82'
ADD PARTY REJECT
X'83'
DROP PARTY
X'84'
DROP PARTY ACKNOWLEDGE

Miscellaneous Messages:

X'7D'
STATUS
X'75'
STATUS ENQUIRY
8
Bit 1 — Extension
B'1... ....'
Extension
Bits 2 and 3 — Spare
B'.0.. ....'
Spare
B'..0. ....'
Spare
Bit 4 — Flag
B'...0 ....'
Message instruction field is not significant. Regular error handling procedures apply. Ignore action indicator field.
B'...1 ....'
Follow explicit instructions in the action indicator field that supersedes regular error handling procedures.
Bit 5 — Spare
B'.... .0..'
Spare
Bit 6 — Spare
B'.... .0..'
Spare
Bits 7 and 8 — Action Indicator
B'.... ..00'
Clear call
B'.... ..01'
Discard and ignore
B'.... ..10'
Discard and report status
B'.... ..11'
Reserved