IBM0830S
ONCODE=oncode-value An I/O error occurred during a CLOSE operation.

Explanation

An I/O error occurred while a VSAM close routine was either reading or writing a catalog record, or completing an outstanding I/O request.

The ONCODE associated with this message is 1011.

System action

The ERROR condition is raised.

Programmer response

If the problem is related to an insufficient amount of virtual storage available to VSAM, try running the job with a larger REGION size. The access method services VERIFY command can be used to obtain more information pertaining to the error. Refer to the MVS/DFP Access Method Services manual for details.

Symbolic Feedback Code

IBM0PU