FSUM2070I
Special characters may appear incorrect on the terminal. The length of the codeset string (codeset-length) in the character conversion table is too long.

Explanation

The field containing the codeset name or locale name in the character conversion table is 64 bytes long. There is a separate length field in the table, which specifies the actual number of bytes used in the codeset name or locale name string. The specified string length was more than 64 bytes.

In the message text:
codeset-length
The length of the codeset string specified in the character conversion table.

System action

The OMVS command continues. Characters in error messages and the help panel will not be converted from code page 1047 to the correct 3270 code page before they are written to the terminal. Certain special characters may appear incorrect on the 3270 screen.

System programmer response

This error normally occurs only when using customized character conversion tables. Fix the length field in the customized table so that matches the number of characters in the codeset name or locale name string. The maximum possible length is 64 characters.

User response

If the CONVERT keyword on the OMVS command was used to override the default character conversion table, specify a different table. If the correct table was specified, contact the system programmer.