FSUM1247
Pipe pipename has been closed

Explanation

There was a timeout writing to the pipe because the pipe was blocked for more than 2 seconds. The pipe has been closed and the syslogd rule with this pipe as its destination has been disabled.
pipename
Is the name of the pipe that has been closed.

System action

syslogd continues to run but will no longer attempt to write log messages to the pipe.

Operator response

Check the application that reads the pipe to be sure it is running. If it is not running, it may need to be restarted. After restarting the application, restart syslogd to resume logging to the pipe.

System programmer response

Check the reading application to be sure it is running with the proper amount of CPU resource. It may need more CPU time to be able to keep up with the amount of data being written to the pipe by syslogd. Make the necessary adjustments and restart syslogd to resume logging.

User response

Not applicable.

Problem determination

See System Programmer Response.

Module

syslogd.c

Example

FSUM1247 Pipe /tmp/mypipe has been closed

Source

z/OS® Communications Server TCP/IP: Syslogd

Routing code

Not applicable

Descriptor code

Not applicable

Automation

Not applicable