The component identifier is RSN_BDCFS. The module halfword identifier is X'5B21'.
The global reason codes: None
The local reason codes:
Value | Description |
---|---|
RSN_BDCFS + X'101' | RSN_BDCFS_Add_Rcvy_Failed Stacking a local recovery environment to the SSF Recovery stack was unsuccessful. Probable cause: Possible programming error. Action: Send the problem to IBM® Support. |
RSN_BDCFS + X'102' | RSN_BDCFS_Sync_Failed Call to sync to process RNODEs on sync chain failed. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'103' | RSN_BDCFS_Scan_Block_Failure Exit routine for the Unmount RNODE scan function failed. Probable cause: Problem might have occurred while freeing RNODEs. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'104' | RSN_BDCFS_Scan_RNODE_Error Error in SSF occurred during the unmount RNODE scan. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'105' | RSN_BDCFS_Delete_RNODE_Hash_Error Error occurred while deleting the RNODE hash table. Probable cause: SSF Common Hashing Facility failed. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'106' | RSN_BDCFS_CLM_Failed Nullifying the allocation latch in the RFS failed. The RFS is the HFS file system control block. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'107' | RSN_BDCFS_Disconn_IMF_Failed Disconnecting from AD failed. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'108' | RSN_BDCFS_IOM_Unmnt_Failed Disconnecting from the I/O Manager mount failed. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'109' | RSN_BDCFS_Disc_VDF_Failed Freeing VDF storage failed. Probable cause: Internal logic error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'110' | RSN_BDCFS_Free_Buffer_Failed. FreeBuffer returns with error. Probable cause: FreeBuffer function encounters some errors. Action: Collect the dump or error information and send the problem to IBM Support. |
RSN_BDCFS + X'111' | RSN_BDCFS_Internal_Error Recovery cleanup has been called even though there was no error condition. Probable cause: Programming error. Action: Send the problem to IBM Support. |
RSN_BDCFS + X'112' | RSN_BDCFS_INVALID_RFS Disconnect File System was called to disconnect an invalid file system. Probable cause: An Internal Logic Error. Action: Send the problem to IBM Support. |