Convert back to PPRC extended distance mode during peak hours

If you want to later convert back to extended distance mode from synchronous mode, follow these steps:

  1. Suspend the volume pairs issuing the following CSUSPEND command.
    CSUSPEND DEVN(X'F41') PRIM(X'A763' FCA76 X'6B' X'03') 
      SEC(X'A762' FCA76 X'1E' X'02') PRIMARY
  2. Establish the volume pairs in extended distance mode by issuing a CESTPAIR command with MODE(RESYNC) OPTION(XD) specified.
    CESTPAIR  DEVN(X'F41') PRIM(X'A763' FCA76 X'6B' X'03') 
      SEC(X'A762' FCA76 X'1E' X'02')  
      MODE(RESYNC) MSGREQ(NO) OPTION(XD)