CREATE PIPELINE
Define a PIPELINE in the local CICS® region.
Conditions: INVREQ, LENGERR, NOTAUTH
Description
The CREATE PIPELINE command installs a PIPELINE definition with the attribute specified on the command. It does not use a resource definition stored in the CSD. If there is already a PIPELINE with the name you specify in the local CICS region, and the existing PIPELINE is disabled, the new definition replaces the old one; if an existing PIPELINE is not disabled, the CREATE command fails.
A syncpoint is implicit in CREATE PIPELINE processing, except when an exception condition is detected early in processing the command. Uncommitted changes to recoverable resources made up to that point in the task are committed if the CREATE executes successfully, and rolled back if not. See Creating resource definitions for other general rules governing CREATE commands.
Options
- ATTRIBUTES(data-value)
- Specifies the attributes of the PIPELINE being added. The list of attributes must be coded as a single character string using the syntax shown in PIPELINE attributes. See The ATTRIBUTES option for general rules for specifying attributes, and PIPELINE attributes for details about specific attributes.
- ATTRLEN(data-value)
- Specifies the length in bytes of the character string supplied in the ATTRIBUTES option, as a halfword binary value. The length must not exceed 32 767 bytes.
- LOGMESSAGE(cvda)
- Specifies whether CICS logs the attributes used for the resource that is created. CVDA values are as follows:
- LOG
- The resource attributes are logged to the CSDL transient data queue.
- NOLOG
- The resource attributes are not logged.
- PIPELINE(data-value)
- Specifies the 8-character name of the PIPELINE definition to be added to the CICS region.
Conditions
- INVREQ
- RESP2 values:
- n
- There is a syntax error in the ATTRIBUTES string, or an error occurred during either the discard or resource definition phase of the processing. The RESP2 value is associated with a message written to the transient data queue CSMT which identifies more precisely the nature of the error. See RESP2 values for CREATE and CSD commands for information on RESP2 values.
- 200
- The command was executed in a program defined with an EXECUTIONSET value of DPLSUBSET or a program invoked from a remote system by a distributed program link without the SYNCONRETURN option.
- 612
- Installation of this PIPELINE failed because it already exists
- LENGERR
- RESP2 values:
- 1
- The length you have specified in ATTRLEN is negative.
- NOTAUTH
- RESP2 values:
- 100
- The user associated with the issuing task is not authorized to use this command.