DFHFC6007 date time applid Attempt by {CICS | user} to {quiesce | unquiesce} a data set failed because the SMSVSAM server is not available. Data set dsname

Explanation

A request to VSAM RLS to quiesce or unquiesce base data set dsname throughout the sysplex has failed because the SMSVSAM server address space is not available.

System action

CICS processing continues. The SMSVSAM server address space should attempt to restart automatically.

The quiesce state of the data set in the ICF catalog is unpredictable.

User response

The SMSVSAM server address space should normally restart itself. If it does not, restart the SMSVSAM server address space manually. Then issue an EXEC CICS SET DSNAME command or the CEMT equivalent to set the quiesce state in the ICF catalog to quiesced or unquiesced as desired.

If the SMSVSAM server address space fails to restart, there may be a more severe error. In this case, you need assistance from IBM. See Working with IBM to solve your problem for guidance on how to proceed.

Module

DFHFCQS

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. Value chosen from the following options:
  5. Value chosen from the following options:
  6. dsname

Destination

CSFL and Console