DELETE COUNTER and DELETE DCOUNTER

Delete the named counter from the specified pool. Use COUNTER for fullword signed counters and DCOUNTER for doubleword unsigned counters.

DELETE COUNTER

Read syntax diagramSkip visual syntax diagramDELETE COUNTER( name)POOL( name)NOSUSPEND

Conditions: BUSY, INVREQ

This command is threadsafe.

DELETE DCOUNTER

Read syntax diagramSkip visual syntax diagramDELETE DCOUNTER( name)POOL( name)NOSUSPEND

Conditions: BUSY, INVREQ

This command is threadsafe.

Description

These commands delete the named counter from the specified pool.

Options

COUNTER(name)
Specifies the 16-byte name of the fullword counter name field. The name can contain upper case letters, digits or underscore characters including the symbols $, #, and @, padded to 16 bytes with trailing spaces. Note that the name cannot start with a number or an underscore. It is recommended that the name should start with a systematic prefix unique to the application.  Any counters used by CICS® itself use the prefix DFH. 
DCOUNTER(name)
Specifies the 16-byte name of the doubleword counter name field. The name can contain upper case letters, digits or underscore characters including the symbols $, #, and @, padded to 16 bytes with trailing spaces. Note that the name cannot start with a number or an underscore. It is recommended that the name should start with a systematic prefix unique to the application. Any counters used by CICS itself use the prefix DFH.
NOSUSPEND
Specifies an immediate return to the application program during a coupling facility structure rebuild. If you omit the NOSUSPEND parameter, the request is retried until it is successful. If you specify NOSUSPEND, the request fails immediately, and CICS returns BUSY, RESP2=500.
POOL(poolname)
Specifies an 8-character string to use as a pool selection parameter to select the pool in which the named counter resides. The string can be a logical pool name, or the actual pool name.

Valid characters for the pool selector string are A through Z, 0 through 9, $ @ # and _ (underscore). If name is a variable that contains a name that is less than 8 characters, the name must be padded with trailing blanks.

This parameter is optional. If you omit the name of the pool, a pool selector value of 8 blanks is assumed.

If there is no matching entry in the DFHNCOPT options table, CICS uses the name specified on the NCPLDFT system initialization parameter, which specifies the default named counter pool.

For information about generating a named counter options table using the DFHNCO macro, see Named counter servers.

Conditions

128 BUSY
RESP2 values:
500
The NOSUSPEND option was specified on the command, and the coupling facility structure is not currently available during a rebuild.

Default action: terminate the task abnormally.

16 INVREQ
RESP2 values:
201
Named counter not found.
301
The server has reported an error code that is not understood by the named counter interface. Generally, this is not possible unless the interface load module, DFHNCIF, is at a lower maintenance or release level than the server itself.
303
An unexpected error, such as structure failure or loss of connectivity, has occurred on a macro used to access the coupling facility. Further information is in message DFHNC0441 in the application job log.
304
The pool selection parameter specified in the program cannot be resolved to a valid server name using the current options table.
305
The interface cannot establish a connection to the server for the selected named counter pool. Further information is in an AXM services message (AXMSCnnnn) in the application job log.
306
An abend occurred during server processing of a request. Further information is in a message in the application job log and the server job log.
308
The DFHNCOPT options table module, required to resolve a pool name, cannot be loaded.
309
During processing of the options table, the named counter interface encountered an unknown entry format. Either the options table is not correctly generated, or the DFHNCIF interface load module is not at the same release level as the options table.
310
An options table entry that matches the given pool name specified a user exit program, but the user exit program is not link-edited with the options table and cannot be loaded.
311
A response from the named counter server to the client region interface module, DFHNCIF, indicates that a system-managed rebuild is in progress but the EXEC CICS interface does not recognize the condition. This means that the CICS region is at CICS TS 2.1 or earlier.
403
The POOL parameter contains invalid characters or embedded spaces.

Default action: terminate the task abnormally.