Dual-purpose resource definition for transient data

You cannot specify TYPE=REMOTE for transient data queues.

Instead, you may want to consider dual-purpose resource definition (see Shared resources for intercommunication). Dual-purpose resource definition can be used with transient data definitions. Figure 1 gives an example of dual-purpose resource definition for transient data resources.

If the definition shown in Figure 1 is installed in a system called CICQ, that definition becomes a local intrapartition queue (the value of REMOTESYSTEM is CICQ).

If the definition shown in Figure 1 is installed in a system other than CICQ, the definition becomes a REMOTE queue.
Figure 1. Dual-purpose resource definition for transient data
 TDqueue        : TDQ1
 Group          : Example
 DEscription  ==>
 TYPE         ==> Intra                         Extra | INTra | INDirect
EXTRA PARTITION PARAMETERS
 DAtabuffers    :                               1-255
 DDname         :
 DSname         :
 Sysoutclass    :
 Erroroption    :                               Ignore | Skip
 Opentime       :                               Initial | Deferred
 REWind         :                               Leave | Reread
 TYPEFile       :                               Input | Output | Rdback
 RECORDSize     :                               0-32767
 BLOCKSize      :                               0-32767
 RECORDFormat   :                               Fixed | Variable
 BLOCKFormat    :                               Blocked | Unblocked
 Printcontrol   :                               A | M
 DIsposition  :                                 Shr | Old |Mod
INTRA PARTITION PARAMETERS
 Atifacility  ==> Terminal           Terminal | File | System
 RECOVstatus  ==> Logical            No | Physical | Logical
 Facilityid   ==> FR1
 TRAnsid      ==>
 TRIggerlevel ==> 00001              0-32767
 Userid       ==>
 
 INDOUBT ATTRIBUTES
 WAIT         ==> Yes                           Yes|No
 WAITAction   ==> Reject                        Queue|Reject
 
 INDIRECT PARAMETERS
 Indirectname :
 
 REMOTE PARAMETERS
 REMOTEName   ==> FR1 
 REMOTESystem ==> CICQ
 REMOTELength ==>                                        0-32767