DFHIIPA$, DFHIIP1$ executable module
Entry points
DFHIIPNA
Called by
DFHMCP
Description
The non-3270 input mapping program performs all BMS input mapping functions for all devices except the 3270. On exit from the module, the input data has been mapped into a newly acquired TIOA that is returned to the application program and is then addressable using BMS DSECTs in the application.
The main subsections of DFHIIP are:
IIMID - GETMAINs TIOA to return to user, and maps
page buffer into it using specified map.
IIREAD - Reads input data, issuing DFHTC or DFHDI
requests to get data from the terminal.
IISCAN - Scans data stream for device-dependent
control characters and creates page
buffer.