FEPI RESP2 values

RESP2 values are used in the EVENTVALUE area of FEPI transient data queue records and returned by the RESP2 option of FEPI commands.

For details of the error conditions and related RESP2 values for each FEPI command, see the command definitions in FEPI system programming reference and FEPI application programming reference.

Declarations for the RESP2 values are provided in the following copy books:
  • DFHSZAPA for Assembler language
  • DFHSZAPO for COBOL
  • DFHSZAPP for PL/I
  • DFHSZAPC for C.
Table 1. RESP2 values
Numerical order Data
1 INQUIRE START, NEXT, or END command not valid here:
START
Browse of this resource type already in progress
NEXT
INQUIRE START not issued
END
INQUIRE START not issued.
2 All resource definitions have been retrieved.
10 Command bypassed by user exit.
11 FEPI not installed or not active.
12 CICS® shutting down, command not allowed.
13 FEPI not available.
14 FEPI busy or cannot get storage.
15 Unknown command.
16 Internal problem.
17 FEPI cannot get storage for user exit parameters.
18 Command failed because of operator or system action.
30 POOL name not known.
31 POOL name out of service.
32 TARGET name not known.
33 TARGET name out of service.
34 TARGET name required but not specified.
35 Pool name is unsuitable for temporary conversations. It has CONTENTION(LOSE) or INITIALDATA(INBOUND) but no begin-session handler.
36 No suitable session available and in service.
40 [FROM]FLENGTH value is negative, zero, or more than MAXFLENGTH value for pool.
41 ESCAPE value not valid.
50 Inbound data with ‘begin bracket' to be received.
51 Attention identifier (AID) not valid.
52 Cursor position not valid.
53 Code points in formatted data not valid.
54 Attribute positions or values in send data not valid.
55 Key stroke escape sequence in send data not valid.
56 Field validation (mandatory fill, mandatory enter, trigger) failed.
57 Input is inhibited.
58 z/OS® Communications Server VTAM® SEND failed.
59 DBCS data rules violated.
60 MAXFLENGTH value negative, or greater than MAXFLENGTH value for pool.
61 FLENGTH value negative or greater than 128.
62 TRANSID name not valid.
63 TERMID name not valid.
70 FIELDLOC or FIELDNUM value negative or not valid.
71 z/OS Communications Server VTAM RECEIVE failed.
72 RECEIVE FORMATTED processing found invalid, or unexpected data while interpreting the 3270 data stream for a WRITE, ERASE/WRITE, ERASE/WRITE ALTERNATE, or WRITE STRUCTURED FIELD command code.
80 CONTROL value not valid.
81 VALUE not valid: omitted when required; included when not required; or unsuitable for specified CONTROL.
82 SENSEDATA option omitted when required, or specified when not required.
90 Definite response type did not match what was required.
91 Only NORMALRESP or EXCEPTRESP allowed at this point in conversation.
92 Response to STSN SET was not positive.
93 Only STSN allowed at this point in conversation.
94 Only STSN or NORMALRESP allowed at this point in conversation.
95 CONTROL value not allowed at this point in conversation.
100 Not authorized to issue command.
110 SERVSTATUS value not valid.
111 ACQSTATUS value not valid.
115 POOL name not known.
116 TARGET name not known.
117 NODE name not known.
118 Unknown connection (TARGET and NODE names known, but not in a common POOL).
119 Request failed for one or more items in list. Detailed errors reported to TD queue for monitor to handle.
130 TARGETNUM value negative, zero, or not valid.
131 NODENUM value negative, zero, or not valid.
132 POOLNUM value negative, zero, or not valid.
140 DEVICE value not valid.
141 CONTENTION value not valid.
142 INITIALDATA value not valid.
143 UNSOLDATACK value not valid.
144 MSGJRNL value not valid.
150 FORMAT value not valid or unsuitable for specified device.
153 STSN name not valid or STSN unsuitable for specified device.
154 BEGINSESSION value not valid.
155 UNSOLDATA value not valid.
156 EXCEPTIONQ value not valid.
157 FJOURNALNUM value not valid.
158 MAXFLENGTH value not valid.
159 ENDSESSION name not valid.
160 PROPERTYSET name not valid.
162 POOL name not valid.
163 NODE name not valid.
164 TARGET name not valid.
167 APPL name not valid.
170 PROPERTYSET name already exists.
171 PROPERTYSET name not known.
172 POOL name already exists.
173 NODE name already exists.
174 TARGET name already exists.
175 Connection already exists.
176 z/OS Communications Server VTAM OPEN NODE failed.
177 z/OS Communications Server APPLID already known.
178 FJOURNALNAME value not valid.
182 Session unbound, unrecoverable.
183 Session unbound, recoverable.
184 Session unbound, error.
185 Session unbound, bind coming.
186 Session unbound.
187 Lost terminal.
188 CLEANUP, abnormal.
189 CLEANUP.
190 UNBIND error.
191 SETUP error.
192 SSCP error.
193 SLU error.
194 PLU error.
195 BIND error.
196 CINIT error.
197 REQSESS error.
198 REQSESS inhibited.
199 REQSESS not available.
210 Option not valid for SLU P.
211 Option not valid for SLU2.
212 Wrong data format for conversation.
213 Command has timed out.
214 CICS shutting down, conversation should be ended.
215 Session lost.
216 Error occurred on previous SEND command.
220 SEND or CONVERSE command not allowed at this point in conversation.
221 RECEIVE command not allowed at this point in conversation.
223 START command not allowed at this point in conversation.
224 Only ISSUE or FREE allowed at this point in conversation.
230 SNA CLEAR command received.
231 SNA CANCEL command received.
232 SNA CHASE command received.
233 Exception response received.
234 Exception request received.
240 Conversation ID unknown or not owned by task.
241 TIMEOUT value negative or not valid.
250 Passticket not built successfully.
251 CICS ESM interface not initialized.
252 Unknown return code in ESMRESP from the ESM.
253 Unrecognized response from CICS security modules.
254 Function unavailable.
259 No signed-on user.