DFHTD1260 applid No DD statement for intrapartition data set ddname

Explanation

CICS is unable to open the intrapartition data set ddname because no DD statement has been provided.

System action

During a cold or initial start, transient data initialization continues until any transient data queue resource definitions have been processed. Any intrapartition queues found are not installed and message DFHTD1217 is issued for each install failure encountered. At the end of TD initialization, message DFHTD0102 is issued. If no other initialization errors occur, message DFHSI1522 is issued.

For all other starts, TD checks the catalog to see if DFHINTRA had opened successfully on the previous CICS run. If it did, initialization is terminated. If it did not, TD initialization continues normally.

User response

During a cold or initial start, respond GO or CANCEL to message DFHSI1522.

Modify the CICS JCL to add a DD statement defining the intrapartition data set (DFHINTRA).

Module

DFHTDRP

XMEOUT parameters/Message inserts

  1. applid
  2. ddname

Destination

Console