DFHPI2005 E date time applid tranid The installation of SCACOMPOSITE resource_name in the BUNDLE resource bundle_name did not complete successfully. A binding attempted to wire to a target with an incompatible binding type. Target: target ,Binding:binding_name .
Explanation
The CICS handling program, DFHPICA, for the 'http://www.ibm.com/xmlns/prod/cics/bundle/SCACOMPOSITE' type failed to create resource resource_name in the BUNDLE resource bundle_name due to an error in the contents of SCDL. The binding binding_name tried to wire to a service or reference which had an incompatible binding type. The most common cause of this is trying to mix a binding.ws with binding.cics.
System action
The resource is set to a disabled state. The associated BUNDLE is set to a disabled state.
User response
Correct the SCDL or the indicated resource problem. Discard the BUNDLE and reinstall.
Module
DFHPICAXMEOUT parameters/Message inserts
- date
- time
- applid
- tranid
- resource_name
- bundle_name
- target
- binding_name
Destination
CPIO