00E8011F
Explanation
The allied address space task primary ESTAE was entered without a subsystem diagnostic work area (SDWA) provided by MVS™ RTM.
System action
Abnormal termination of the allied address space is continued.
Operator response
Notify the system programmer.
System programmer response
If you suspect an error in DB2®, you might need to report the problem. For information about identifying and reporting the problem, see Collecting diagnostic data.
The recovery routine for the CSECT issuing this reason code records information in the variable recording area (VRA).
Problem determination
Collect the following diagnostic items:
- Dynamic dump, taken to SYS1.DUMPxx data set, by DB2 (04E and 04F abends).
- SVC dump (or system dump), taken to SYS1.DUMPxx data set, as result of an operator-initiated dump command or SLIP trap exit.
- Listing of SYS1.LOGREC data set, obtained by executing IFCEREP1.