Setting up HP Quality Center 11.x and 12.0 client

Setting up HP ALM server for auto deployment of files to the clients is a simple way to enable functionality for any client that is accessing the server. In some organizations, however, auto deployment is not a feasible scenario (for example, if security policies prohibit clients from having local admin privileges). In such cases, clients that require the integrated functionality can have the plug-in files deployed manually. In this way, the plug-in files can be targeted to only the clients that require them, rather than all HP Quality Center users.

About this task

To deploy the required files to a HP Quality Center client:

Procedure

  1. Deploy the IBM® Rational® Integration Tester installation file IntegrationTester.ini to the HP ALM server.
    1. Extract the QualityCenterServerDist11.zip (for HP Quality Center 11.0) file or QualityCenterServerDist11_5.zip (for HP Quality Center 11.5 and 12.0) to a temporary location.
    2. Copy the IntegrationTester.ini from the GHTesterQC11Integration\CustomTestTypes to the ALM Deployment Directory\application\20qcbin.war\CustomTestTypes
    Note: For detailed information, see Setting up the HP Application Lifecycle Management 11.x server. Do not copy any other files other than the IntegrationTester.ini file.
  2. Log in to the HP Quality Center using a browser and verify that you have all the required files in the client workstation.
  3. Log out from the HP Quality Center and locate the HP ALM-Client folder. By default, the location is C:\Users\user_name\AppData\Local\HP\ALM-Client\server_name , where the user_name is your operating system user name and the server_name is the name of the HP Quality Center server to which the client is connected to.
  4. Extract the contents of QualityCenterServerDist11-client-only.zip or QualityCenterServerDist11_5-client-only.zip to the ALM-Client folder.
  5. Open the command prompt, change the directory to ALM-Client and run the script RITIntegrationSetup.cmd. Each of the required components are registered in the client workstation. For more information, see the readme file that is provided with the QualityCenterServerDist11-client-only.zip