Kpp_TEMS_HUB_TCP_HOST
Use the KPP_TEMS_HUB_TCP_HOST parameter to specify the hostname or IP address of the system where the primary Tivoli® Enterprise Monitoring Server (local or remote) is running.
- Required or optional
- Optional. Required for remote Tivoli Enterprise Monitoring Servers that use TCP/IP for communications with the hub monitoring server
- Location where the parameter value is stored
- In the KDCSSITE member in the rhilev.midlev.rtename.RKANPARU
library
- Parameter name
AGLOCCN
(Connect agent to local TEMS)- Default value
- None
- Permissible values
- Character string, maximum length 32
- Batch parameter name
- KPP_CMS_HUB_TCP_HOST
- PARMGEN name
- KPP_TEMS_HUB_TCP_HOST
- PARMGEN classification
- Values that describe the Primary TEMS the Agent will connect to
- Description
-
Hostname of the primary TEMS
This parameter specifies the hostname or IP address of the system where the primary Tivoli Enterprise Monitoring Server (local or remote) is running. The value specified for this parameter must match the value set for the KDS_TEMS_TCP_HOST parameter in the runtime environment where the hub is configured, or the value set for an equivalent parameter of a distributed hub.
- Related parameters
- None