PCIe adapter placement rules and slot priorities for the 8335-GTG, 8335-GTH, or 8335-GTX system
Find information about the placement rules and slot priorities for the Peripheral Component Interconnect Express (PCIe) adapters that are supported for the system.
PCIe slot descriptions
The system provides PCIe generation 4 slots. Table 1 lists the PCIe adapter slots and details for the system as viewed from the rear and going from left to right. Figure 1 shows the rear view of the system with the PCIe adapter slots. The system supports half-height, half-length and short (low-profile) PCIe adapters.
Slot identification | Description | Adapter size | Processor module | Coherent Accelerator Processor Interface (CAPI) |
---|---|---|---|---|
1 | PCIe4 x4 | Half-height, half-length | CPU 0 | No |
2 | PCIe4 x8 | Half-height, half-length | CPU 1 (shared) | Yes |
3 | PCIe4 x16 | Half-height, half-length | CPU 1 | Yes |
4 | PCIe4 x16 | Half-height, half-length | CPU 0 | Yes |
PCIe adapter placement rules
Feature code | Description | Slot priorities (slot identification 1-4) | Maximum number of adapters supported |
---|---|---|---|
EC2R1 | PCIe3 2-port 10 Gb NIC and RoCE SR/CU adapter (FC EC2R and EC2S; CCIN 58FA); Adapter FRU number: 01FT759 | 3, 4, 2 | 3 |
EC2T1 | PCIe3 2-port 25/10 Gb NIC and RoCE SR/CU capable adapter (FC EC2T and EC2U; CCIN 58FB); Adapter FRU number: 01FT753 | 3, 4, 2 | 3 |
EC3L | PCIe3 2-port 100 GbE (NIC and RoCE) QSFP28 adapter (FC EC3L and EC3M; CCIN 2CEC); Adapter FRU number: 00WT078 | 4, 3 | 2 |
EC5A | Non-volatile Memory PCIe3 x8 1.6 TB SSD NVMe adapter (FC EC5A; CCIN 58FC); Adapter FRU number: 01DH573 | 2, 3, 4 | 3 |
EC5C | PCIe3 x8 Non-Volatile Memory 3.2 TB SSD NVMe adapter (FC EC5C and EC5D; CCIN 58FD); Adapter FRU number: 01DH361 | 4, 3, 2 | 3 |
EC5E | PCIe3 x8 Non-Volatile Memory 6.4 TB SSD NVMe adapter (FC EC5E and EC5F; CCIN 58FE); Adapter FRU number: 01DH365 | 4, 3, 2 | 3 |
EC5G | Non-volatile Memory PCIe3 x8 1.6 TB SSD NVMe adapter (FC EC5A and EC5G; CCIN 58FC); Adapter FRU number: 01LK427 | 4, 3, 2 | 3 |
EC62 | PCIe4 x16 1-Port EDR 100 Gb InfiniBand ConnectX-5 CAPI capable adapter (FC EC62; CCIN 2CF1); Adapter FRU number: 00WT179 | 2, 3, 4 | 3 |
EC64 | PCIe4 x16 2-Port EDR 100 Gb InfiniBand ConnectX-5 CAPI capable adapter (FC EC64; CCIN 2CF2); Adapter FRU number: 00W176 | 2, 3, 4 | 3 |
EC67 | PCIe4 x16, 2-port 100 Gb RoCE En ConnectX-5 adapter (FC EC66 and EC67; CCIN 2CF3); Adapter part number: 01FT742 | 4, 3, 2 Note: If slot 2 is populated by FC EC64 adapter, use slots 4 and 3 for
EC67.
|
3 |
EL3Z | PCIe2 LP 2-port 10 GbE BaseT RJ45 adapter (FC EL3Z and FC EN0X; CCIN 2CC4); Adapter FRU number: 00E2714 | 3, 4, 2, 1 | 4 |
EL43 | PCIe3 LP 16 Gb 2-port Fibre Channel adapter (FC EL43 and FC EN0B; CCIN 577F); Adapter FRU number: 00E3496 | 3, 4, 2 | 3 |
EL4M | PCIe2 LP 4-port 1 GbE adapter (FC 5260, FC 5899, FC EL4L, and FC EL4M; CCIN 576F); Adapter FRU number: 74Y4064 | 1, 2, 3, 4 | 4 |
EL5V | PCIe3 8x 2-port Fibre Channel (32 Gb/s); (FC EN1A, FC EN1B, FC EL5V, and EL5U; CCIN 578F); Adapter FRU number: 01FT704 | 3, 4, 2 | 3 |
EN0T | PCIe2 LP 4-port (10 Gb + 1 GbE) SR+RJ45 adapter (FC EN0T; CCIN 2CC3); Adapter FRU number: 00E2715 | 3, 4, 2, 1 | 4 |
EN0V | PCIe2 LP 4-port (10 Gb + 1 GbE) Copper SFP+RJ45 adapter (FC EN0V; CCIN 2CC3); Adapter FRU number: 00E2715 | 3, 4, 2, 1 | 4 |
1 The adapter is only supported on the 8335-GTH and 8335-GTX systems. * Review SMPI software restrictions that might prevent you from using more than four RMDA interfaces. Slot 2 is a bifurcated slot. A two port adapter is configured as four RDMA interfaces; two from CPU 0 and two from CPU 1. Therefore the adapters in slot 4, 3, and 2 have 8 RDMA interfaces. ** Due to airflow restrictions, the adapter configuration is restricted to slots 4 and 3. |