SAS subsystem configuration details

Learn about the features and locations of the SAS subsystem parts in the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S system.

Use this information in conjunction with your specific system and operating system documentation.

Feature locations for the SAS subsystem parts in the base function storage configuration

Figure 1 and Table 1 provide information about the supported SAS features and the part locations in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems.
Figure 1. SAS subsystem parts in the base function storage configuration in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems
SAS subsystem parts in the base function storage configuration
Table 1. SAS subsystem parts in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems with the base function storage configuration
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 SAS RAID internal adapter 6 Gb EJ1F 57D7 P1-C49
B, C Base function disk drive backplane with 8 SFF bays EJ1F 2D36 P2-D1 through P2-D8
Table 2 and Figure 2 provide information about the supported SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems.
Figure 2. SAS subsystem parts in the base function storage configuration in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems
SAS subsystem parts in the base function storage configuration
Table 2. SAS subsystem parts in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems with the base function storage configuration
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 SAS RAID internal adapter 6 Gb EJ1C 57D7 P1-C49
B, C Base function disk drive backplane with 12 SFF bays EJ1C 2D34 P2-D1 through P2-D12 for disk bays
D One RDX bay EU00   P3-D1

Feature locations for the SAS subsystem parts in systems with base function storage configuration with the split-disk feature

Figure 3 and Table 3 provide information about the supported SAS features and the part locations in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems.
Figure 3. SAS subsystem parts in the base function storage configuration with the split-disk feature in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S system
SAS subsystem parts in the base function storage configuration with the split-disk feature
Table 3. SAS subsystem parts in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems with the base function storage configuration with split-disk feature
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 SAS RAID internal adapter 6 Gb (quantity 2) EJ1H 57D7 P1-C49, P1-C50
B, C1, C2 Base function disk drive backplane with 8 SFF bays that are split into two groups of 4 disk bays (C1 and C2) EJ1H 2D36 P2-D1 through P2-D8
Table 4 and Figure 4 provide information about the supported SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems.
Figure 4. SAS subsystem parts in systems with base function storage configuration with the split-disk feature in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S
SAS subsystem parts in the base function storage configuration with the split-disk feature

Table 4. SAS subsystem parts in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems with the base function storage configuration with split-disk feature
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 SAS RAID internal adapter 6 Gb (quantity 2) EJ1E 57D7 P1-C49, P1-C50
B, C1, C2 Base function disk drive backplane with 12 SFF bays that are split into two groups of 6 disk bays (C1 and C2) EJ1E 2D34 P2-D1 through P2-D12 for disk bays
D One RDX bay EU00   P3-D1

Feature locations for the SAS subsystem parts in systems with expanded function storage configuration

Figure 5 and Table 5 provide information about the supported SAS features and the part locations in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems that have the expanded function storage configuration.
Figure 5. SAS subsystem parts in a system with expanded function storage configuration in a 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S
SAS subsystem parts in a system with the expanded function storage configuration
Table 5. SAS subsystem parts in a 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S system with the expanded function storage configuration
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 cache SAS RAID internal adapter 6 Gb (quantity 1) EJ1G 57DC P1-C49
B, C Expanded function disk drive backplane with 8 SFF bays EJ1G 2D36 P2-D1 through P2-D8
E External SAS port cable assembly     P1-C10
G Backup power module card     P1-C49-E1
Figure 6 and Table 6 provide information about the supported SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems.
Figure 6. SAS subsystem parts with the expanded function storage configuration in a 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S system
SAS subsystem parts in a system with the expanded function storage configuration

Table 6. SAS subsystem parts in a 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S system with the expanded function storage configuration
Diagram location Part name Feature code (FC) Customer card identification numbers (CCINs) Physical location codes
A PCIe3 x8 cache SAS RAID internal adapter 6 Gb (quantity 2) EJ1D or EJ1M 57D8 P1-C49, P1-C50
B, C Expanded function disk drive backplane, which supports one of the following options:
  • 18 SFF bays
  • 12 SFF bays
  • EJ1D for 18 SFF bays
  • EJ1M for 12 SFF bays
  • 2D35 for 18SFF bays
  • 6B64 for 12SFF bays

P2-D1 through P2-D18

P2-D1 through P2-D12

E External SAS port cable assembly    

P1-C6

D One RDX bay EU00 EU00

P3-D1

Feature details
SAS RAID adapters
The SAS RAID adapters have the following features:
  • PCI Express (PCIe3) system interface
  • Physical link (phy) speed of 6 Gbps SAS
  • Optimized for SAS disk configurations that use dual paths through dual expanders for redundancy and reliability
  • Adapter managed path redundancy and path switching for multiported SAS devices
  • Embedded PowerPC processor, hardware XOR DMA Engine, and hardware Finite Field Multiplier (FFM) DMA Engine (for Redundant Array of Independent Disks (RAID))
  • Support for RAID 0, 5, 6, and 10 disk arrays
  • Additional features when the PCIe3 x8 cache SAS RAID internal adapter 6 Gb card is installed:
    • Adapters support nonvolatile write cache
    • Support for RAID 5T2, 6T2, and 10T2 tiered disk arrays (depending on the Operating System support)
    • Adapters configured in dual storage IOA or high availability (HA) RAID mode for best reliability and availability
  • RAID disk arrays supported as a boot device
  • Advanced RAID features:
    • Hot spares for RAID 5, 6, 10, 5T2, 6T2, and 10T2 disk arrays
    • Background parity checking
    • Background data scrubbing
    • Disks formatted to 528 or 4224 bytes per sector, providing cyclical redundancy checking (CRC) and logically bad block checking (T10 Data Integrity Fields)
    • Optimized hardware for RAID 5 and 6 sequential write workloads
    • Optimized skip read/write disk support for transaction workloads