SAS subsystem configuration details
Learn about the features and locations of the SAS subsystem parts in the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S system.
Use this information in conjunction with your specific system and operating system documentation.
Feature locations for the SAS subsystem parts in the base function storage configuration
Figure 1 and Table 1 provide information about the supported SAS
features and the part locations in 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9223-22H, or 9223-22S
systems.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 SAS RAID internal adapter 6 Gb | EJ1F | 57D7 | P1-C49 |
B, C | Base function disk drive backplane with 8 SFF bays | EJ1F | 2D36 | P2-D1 through P2-D8 |
Table 2 and Figure 2 provide information about the
supported SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-42H, or 9223-42S systems.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 SAS RAID internal adapter 6 Gb | EJ1C | 57D7 | P1-C49 |
B, C | Base function disk drive backplane with 12 SFF bays | EJ1C | 2D34 | P2-D1 through P2-D12 for disk bays |
D | One RDX bay | EU00 | P3-D1 |
Feature locations for the SAS subsystem parts in systems with base function storage configuration with the split-disk feature
Figure 3 and Table 3 provide information about the supported SAS
features and the part locations in 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9223-22H, or 9223-22S
systems.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 SAS RAID internal adapter 6 Gb (quantity 2) | EJ1H | 57D7 | P1-C49, P1-C50 |
B, C1, C2 | Base function disk drive backplane with 8 SFF bays that are split into two groups of 4 disk bays (C1 and C2) | EJ1H | 2D36 | P2-D1 through P2-D8 |
Table 4 and Figure 4 provide information about the
supported SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-42H, or 9223-42S systems.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 SAS RAID internal adapter 6 Gb (quantity 2) | EJ1E | 57D7 | P1-C49, P1-C50 |
B, C1, C2 | Base function disk drive backplane with 12 SFF bays that are split into two groups of 6 disk bays (C1 and C2) | EJ1E | 2D34 | P2-D1 through P2-D12 for disk bays |
D | One RDX bay | EU00 | P3-D1 |
Feature locations for the SAS subsystem parts in systems with expanded function storage configuration
Figure 5 and Table 5 provide information about the supported SAS
features and the part locations in 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9223-22H, or 9223-22S systems
that have the expanded function storage
configuration.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 cache SAS RAID internal adapter 6 Gb (quantity 1) | EJ1G | 57DC | P1-C49 |
B, C | Expanded function disk drive backplane with 8 SFF bays | EJ1G | 2D36 | P2-D1 through P2-D8 |
E | External SAS port cable assembly | P1-C10 | ||
G | Backup power module card | P1-C49-E1 |
Figure 6 and Table 6 provide information about the supported
SAS features and the part locations in 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-42H, or 9223-42S
systems.
Diagram location | Part name | Feature code (FC) | Customer card identification numbers (CCINs) | Physical location codes |
---|---|---|---|---|
A | PCIe3 x8 cache SAS RAID internal adapter 6 Gb (quantity 2) | EJ1D or EJ1M | 57D8 | P1-C49, P1-C50 |
B, C | Expanded function disk drive backplane, which supports one of the following
options:
|
|
|
P2-D1 through P2-D18 P2-D1 through P2-D12 |
E | External SAS port cable assembly |
P1-C6 |
||
D | One RDX bay | EU00 | EU00 |
P3-D1 |
Feature details
- SAS RAID adapters
- The SAS RAID adapters have the following features:
- PCI Express (PCIe3) system interface
- Physical link (phy) speed of 6 Gbps SAS
- Optimized for SAS disk configurations that use dual paths through dual expanders for redundancy and reliability
- Adapter managed path redundancy and path switching for multiported SAS devices
- Embedded PowerPC processor, hardware XOR DMA Engine, and hardware Finite Field Multiplier (FFM) DMA Engine (for Redundant Array of Independent Disks (RAID))
- Support for RAID 0, 5, 6, and 10 disk arrays
- Additional features when the PCIe3 x8 cache SAS RAID internal adapter 6 Gb card is
installed:
- Adapters support nonvolatile write cache
- Support for RAID 5T2, 6T2, and 10T2 tiered disk arrays (depending on the Operating System support)
- Adapters configured in dual storage IOA or high availability (HA) RAID mode for best reliability and availability
- RAID disk arrays supported as a boot device
- Advanced RAID features:
- Hot spares for RAID 5, 6, 10, 5T2, 6T2, and 10T2 disk arrays
- Background parity checking
- Background data scrubbing
- Disks formatted to 528 or 4224 bytes per sector, providing cyclical redundancy checking (CRC) and logically bad block checking (T10 Data Integrity Fields)
- Optimized hardware for RAID 5 and 6 sequential write workloads
- Optimized skip read/write disk support for transaction workloads