Model 7014-T42, 7014-B42, and 0553 rack

Hardware specifications provide detailed information for your rack, including dimensions, electrical, power, temperature, environment, and service clearances.

Table 1. Dimensions for rack

Rack configuration

Width

Depth

Height1

Weight (empty)

Weight (maximum configuration)

EIA unit capacity

Rack only with side covers

644 mm (25.4 in.)

1016 mm (40.0 in.)

2015 mm (79.3 in.)

261 kg (575 lb)

1597 kg (3521 lb)2 = (1336 kg + 261 kg)

42 EIA units

Rack with standard rear door only

644 mm (25.4 in.)

1042 mm (41.0 in.)

2015 mm (79.3 in.)

273 kg (602 lb)

N/A

N/A

Rack with standard front and rear doors

644 mm (25.4 in.)

1098 mm (43.3 in.)

2015 mm (79.3 in.)

289 kg (636 lb)

N/A

N/A

Rack with FC 6084 OEM front door and standard rear door

644 mm (25.4 in.)

1098 mm (43.3 in.)

2015 mm (79.3 in.)

289 kg (636 lb)

N/A

N/A

Rack with FC 6069 high perforation front door and standard rear door

644 mm (25.4 in.)

1098 mm (43.3 in.)

2015 mm (79.3 in.)

289 kg (636 lb)

N/A

N/A

Rack with FC ERG7 770/780 high perforation front door and standard rear door

644 mm (25.4 in.)

1176 mm (46.3 in.)

2015 mm (79.3 in.)

290 kg (639 lb)

N/A

N/A

Rack with FC 6249 acoustic front and rear doors

644 mm (25.4 in.)

1413 mm (55.6 in.)

2015 mm (79.3 in.)

289 kg (635 lb)

N/A

N/A

Rack with FC 6250 high end appearance front door and standard rear door

644 mm (25.4 in.)

1131 mm (44.5 in.)

2015 mm (79.3 in.)

 

N/A

N/A

Rack with FC ERGB acoustic front door and standard rear door

644 mm (25.4 in.)

1240 mm (48.8 in.)

2015 mm (79.3 in.)

285 kg (627 lb)

N/A

N/A

Rack with FC 6858 heat exchanger rear door and standard front door

644 mm (25.4 in.)

1222 mm (48.1 in.)

2015 mm (79.3 in.)

Empty: 306 kg (675 lb)

Full: 312 kg (688 lb)

N/A

N/A

Rack with FC ERG0 rack extension and standard front and rear doors

644 mm (25.4 in.)

1303 mm (51.3 in.)

2015 mm (79.3 in.)

315 kg (694 lb)

N/A

N/A

Notes:
  1. The top 6U of the rack can be temporarily detached at the client site to make it easier to move the rack through doors or elevators. The top 6U is then reattached to the rack frame to provide the full 42U rack capacity. The rack is approximately 28 cm (11 in.) shorter when the top is removed. For more information about removing the top cover, see Removing the rack top cover. The weight of the top cover is approximately 29 kg (63 lbs).
  2. For more information about rack weight distribution and floor loading, see 7014-T00, 7014-T42, and 0553 rack weight distribution and floor loading.
Table 2. Dimensions for doors

Door model

Width

Height

Depth

Weight

Standard front door

639 mm (25.2 in.)

1946 mm (76.6 in.)

56 mm (2.3 in.)

16 kg (34 lb)

Standard rear door

639 mm (25.2 in.)

1946 mm (76.6 in.)

26 mm (1.0 in.)

13 kg (27 lb)

With acoustic foam: 16 kg (34 lb)

Standard side covers (each)

10 mm (.4 in.)

1740 mm (68.5 in.)

1042 mm (41.0 in.)

18 lbs 8.25 kg(18 lb)

FC 6084 front door (OEM)

639 mm (25.2 in.)

1946 mm (76.6 in.)

56 mm (2.3 in.)

16 kg (34 lb)

FC 6069 front door, high perforation

639 mm (25.2 in.)

1946 mm (76.6 in.)

56 mm (2.3 in.)

16 kg (34 lb)

FC ERG7 front door 770/780 high perforation

639 mm (25.2 in.)

1946 mm (76.6 in.)

134 mm (5.3 in.)

17 kg (37 lb)

FC 6249 acoustic doors, front and rear

639 mm (25.2 in.) each

1946 mm (76.6 in.) each

198 mm (7.8 in.) each

13.6 kg (30 lb) each

FC 6250 high end appearance front door

639 mm (25.2 in.) each

1946 mm (76.6 in.) each

90 mm (3.5 in.)

 

FC ERGB acoustic door, front only

639 mm (25.2 in.)

1946 mm (76.6 in.)

198 mm (7.8 in.)

13.6 kg (30 lb)

FC 6238 high end appearance side covers

10 mm (.4 in.)

1740 mm (68.5 in.)

1042 mm (41.0 in.)

8.5 kg (18 lb)

FC 6858 heat exchanger rear door

639 mm (25.2 in.)

1946 mm (76.6 in.)

147 mm (5.8 in.)

Empty: 29.9 kg (66 lb)

Full: 35.6 kg (78.5 lb)

FC ERG0 8-inch rack extension

647 mm (25.4 in.)

1957 mm (77.1 in.)

203 mm (8.0 in.)

27 kg (58.0 lb)

FC ERG8 ballast weight specify code1

N/A

N/A

N/A

52.1 kg (115 lb)

1 When model 9080-MHE, 9080-MME, 9119-MHE, and 9119-MME servers are ordered with FC ER16 to reserve rack space for future system nodes, FC ERG8 is automatically added to the order.
Table 3. Electrical1
Electrical characteristics Properties
Power source loading maximum in kVA For more information about rack power distribution units and power cord options, see Power distribution unit and power cord options for 7014, 0551, 0553, and 0555 racks.

1 The total rack power can be derived from the sum of the power that is used by the drawers in the rack.

See your individual server or hardware specifications for temperature and humidity requirements.

Rack noise levels depend on the number and type of drawers installed. See your server or hardware specifications for specific requirements.
Note: All rack installations require careful site and facilities planning that is designed to both address the cumulative drawer heat output and provide the airflow volume rates necessary to comply with drawer temperature requirements. All rack installations require careful site and facilities planning that is designed to address both the cumulative drawer heat output and provide the airflow volume rates necessary to comply with drawer temperature requirements. Rack airflow requirements depend on the number and type of drawers installed.
Note: Acoustic doors are available for IBM® racks. Feature code 6248 is available for the 0551 and 7014-T00 racks. Feature code 6249 is available for the 0553 and 7014-T42 racks. The overall sound reduction is approximately 6 dB. The doors add approximately 381 mm (15 in.) to the depth of the racks.

Service clearances

Table 4. Service clearances for 7014-T00, 7014-T42, and 0553 racks

Front

Rear

Sides

915 mm (36 in.)

915 mm (36 in.)

915 mm (36 in.)

Note: Recommended minimum vertical service clearance from the floor is 2439 mm (8 ft).

Figure 1 provides the caster and leveler locations for 7014-T00, 7014-T42, 0551, 0553, and 0555 racks.

Figure 1. Caster and leveler locations
Caster and leveler locations
Note: Rack units are large and heavy and are not easily moved. As maintenance activities require access at both the front and the back, extra room is needed. The footprint illustration does not show the radius of the swinging doors on the I/O rack. A service clearance of 915 mm (36 in.) needs to be maintained on front, rear, and sides of the I/O rack.



Last updated: Tue, February 02, 2021