PGDPART

Look here for information about PGDPART symbolic FRU.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.

  1. Power off the system. See Powering on and powering off the system.
  2. Verify that the power supplies are connected and seated properly. See PWRSPLY.
  3. Power on the system. See Powering on and powering off the system.
  4. Is the reference code 1xxx2600?
    • No: Continue with the next step.
    • Yes: Replace the system backplane. For more information, see System parts. This ends the procedure.
  5. Is the reference code 1xxx2610 or 1xxx2620?
    • No: Continue with step 7.
    • Yes: Continue with the next step.
  6. Perform the action indicated for your system in the following table:
    System: Action:
    5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A Replace the following items, one at a time, until the problem is resolved:
    1. Power supplies at locations Un-Ex.
    2. System backplane at location Un-P1.

    This ends the procedure.

    8408-44E or 8408-E8E Replace the following items, one at a time, until the problem is resolved:
    1. Power supplies at locations Un-Ex.
    2. System backplane at location Un-P2.

    This ends the procedure.

    9080-MHE, 9080-MME, 9119-MHE, or 9119-MME Replace the following items, one at a time, until the problem is resolved:
    1. Voltage regulator module at location Un-P1-C62.
    2. Power supplies at locations Un-Ex.
    3. System backplane at location Un-P1.

    This ends the procedure.

  7. Is the reference code 1xxx1BFF?
    • No: Continue with the next FRU in the failing item list. This ends the procedure.
    • Yes: Continue with the next step.
  8. Perform the action indicated for your system in the following table:
    System: Action:
    8408-44E or 8408-E8E Replace the following items, one at a time, until the problem is resolved:
    1. Power supplies at locations Un-Ex.
    2. System backplane at location Un-P2.
    3. RAID card at location Un-P3.
    4. Power midplane at location Un-P5.

    This ends the procedure.