FWNVR3

Look here for information about FWNVR3 symbolic FRU.

Execution of a command line within the nonvolatile random access memory (NVRAM) configuration variable nvramrc(script) resulted in a "throw" being executed.

This script can be modified by the system firmware SMS utilities, the operating system, PCI adapter ROM code or utility, or an operator (using the open firmware script editing command nvedit).

It might not be possible to resolve the problem without a detailed analysis of the NVRAM script, the current system configuration, and the device tree contents.

  1. This problem can be caused by a SCSI adapter whose SCSI bus ID has changed from the default setting and the adapter no longer appears in the system. This can be caused either by removing a SCSI adapter, or a problem with a SCSI adapter.
    1. On the SMS main menu, select option 5, Change SCSI settings.
    2. On the SCSI utilities menu, select option 2, Change SCSI ID.
      1. Verify the list of SCSI controllers/adapters. If the list is not correct, suspect a problem with adapters that are installed but not listed.
      2. Select the option to "Save" the configuration information.
      3. Restart the system.
    3. If the problem persists, boot the operating system and verify the SCSI bus IDs of the SCSI controllers, and correct if necessary.
    4. Restart the system.
  2. Contact your service support representative for further assistance.

This ends the procedure.




Last updated: Tue, April 21, 2020