DEVICE

The addressed storage device is the failing item.

Complete the following steps.

  1. Is the device location information available in the service action log (SAL)?
    • No: Continue with the next step.
    • Yes: Replace the failing item.
  2. Find the IOP address and the device address. For information, see System reference code format description.
  3. To determine the location of the I/O processor card, see Part locations and location codes and find the diagram of the system unit or the expansion unit. Then, find:
    • The IOP card location that is identified by the direct select address.
    • The addressed storage device location that is identified by the device address.
  4. Replace the failing device. Use the device type to help determine the part number.

This ends the procedure.