DEVBPLN

A device backplane might be failing.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.

Complete the following steps:

  1. Does the SRC that sent you here begin with a 50B1 or are you working with an attached 5887 disk expansion unit?
    • No: Continue with the next step.
    • Yes: Replace the midplane of the 5887 disk expansion unit. See the table at the end of this procedure for location and part number information.
  2. Does the SRC that sent you here begin with a 78D1 or are you working with an attached 5147-024, ESLL, or ESLS storage enclosure?
    • No: Continue with the next step.
    • Yes: Replace the midplane of the 5147-024, ESLL, or ESLS storage enclosure. See the table at the end of this procedure for location and part number information.
  3. Replace the device backplane. See the following table for location and part number information.
    CCIN Type and model Part number Description Location code
    50B1 5887 See System parts. 5887 expansion unit midplane Un-P1
    78D1 5147-024, ESLL, or ESLS See System parts. 5147-024, ESLL, or ESLS storage enclosure midplane Un-P1
      5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A See System parts. Drive backplane Un-P2
  4. Use the following table to determine the part number for the field replaceable unit (FRU).
    CCIN or FFC Type and model Part number Description Location code
      5887 See System parts. 5887 expansion unit midplane Un-P1
      5147-024, ESLL, or ESLS See System parts. 5147-024, ESLL, or ESLS storage enclosure midplane Un-P1



Last updated: Tue, April 21, 2020