CRYPTLP

Cryptographic adapter Licensed Internal Code problem.

The Licensed Internal Code for the cryptographic adapter does not ship with the system.

The Licensed Internal Code is contained within the licensed program 5733-CY3 Cryptographic Device Manager.

Perform one of the following options:

  • If the SRC is B0136615, ensure that this licensed program is loaded on the system. If it is not, vary off the cryptographic adapter, apply the licensed program to the system, and then vary on the cryptographic adapter. The vary-on process might take up to 15 minutes.
  • If the SRC is B0136619, vary off the cryptographic adapter, apply the most recent version of the licensed program to the system, and then vary on the cryptographic adapter. The vary-on process might take up to 15 minutes.

This ends the procedure.




Last updated: Tue, April 21, 2020