AMBTEMP

The system detected a warning or fault due to the ambient room temperature.

For more information about failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to see applicable procedures for your system.

  1. Is the room temperature less than 40°C (104°F)?
    Note: Derate the dry-bulb temperature 1°C per 175 m above 950 m. For more information about environmental requirements, see Hardware specification sheets.
    • No: Notify the customer. The customer must bring the room temperature within normal range. Continue with the next step.
    • Yes: Continue with the next step.
  2. Are the system front and rear doors free of obstructions?
    • No: Notify the customer. The system must be free of obstructions for proper air flow. Continue with the next step.
    • Yes: Continue with the next step.
  3. Ensure that rack fillers are installed in empty rack slots. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue with the next step.
  4. Are you working with reference code 1xxx7201 or has reference code 1xxx7201 been logged?
    • Yes: The room temperature is too high. The customer must fix the room temperature problem identified in step 1. If the customer has fixed the room temperature problem identified in step 1 and a reference code 1xxx7201 is still being logged, continue with the next step.
    • No: Replace the FRU listed in the error log for the SRC you are working with and go to step 6.
  5. Replace the control panel. Use the following table to determine the part number for the field replaceable unit (FRU). Then, continue with the next step.
    Type and model Part number Description Location code
    5148-21L, 5148-22L, 8247-21L, 8247-22L, 8247-42L, 8284-21A, 8284-22A, 8286-41A, or 8286-42A See System parts. Control (operator) panel Un-D1
    8408-44E or 8408-E8E See System parts. Control (operator) panel Un-D1
    9080-MHE, 9080-MME, 9119-MHE, or 9119-MME See System parts. Control (operator) panel Un-P1-C13 of the system control unit
    EMX0 PCIe3 expansion drawer See System parts. Chassis management card Un-P3-C1
  6. After each FRU is replaced, is the error code that sent you to this procedure still reported?
    • No: The problem is resolved. This ends the procedure.
    • Yes: Replace the next failing item in the failing item list. If you replaced all of the items in the failing item list and there is still a problem, contact your next level of support. This ends the procedure.



Last updated: Tue, April 21, 2020