Activating and deactivating LEDs

Use this procedure to activate or deactivate LEDs using Service Focal Point™ for the HMC.

Choose from the following:

Deactivating a system attention LED or partition LED

You can deactivate a system attention LED or a logical partition LED. For example, you might determine that a problem is not a high priority and decide to repair the problem at a later time. However, you want to be alerted if another problem occurs, so you must deactivate the system attention LED so that it can be activated again if another problem occurs.
  1. In the navigation area, open Systems Management.
  2. Open Servers and select the appropriate system.
  3. In the content area, check the box for the appropriate Partition.
  4. Select Tasks, then Operations, and then Manage Attention LED.
  5. Select the appropriate Partition.
  6. Select Deactivate System Attention LED from the Action menu. A confirmation window is displayed that provides the following information:
    • A verification that the system attention LED was deactivated.
    • An indication that there still might be open problems within the system.
    • An indication that you cannot activate the system attention LED.
  7. Select one of the logical partitions in the lower table, and select Deactivate partition LED from the Partition Operations menu. A confirmation window is displayed that provides the following information:
    • A verification that the logical partition LED was deactivated.
    • An indication that there still might be open problems within the logical partition.
    • An indication that you cannot activate the logical partition LED.

Activating or deactivating identify LED

The system provides several LEDs that help identify various components, such as enclosures or field replaceable units (FRUs), in the system. For this reason, they are called identify LEDs.

You can activate or deactivate the following types of identify LEDs:
  • Identify LED for an enclosure If you want to add an adapter to a specific drawer (enclosure), you need to know the machine type, model, and serial number (MTMS) of the drawer. To determine whether you have the correct MTMS for the drawer that needs the new adapter, you can activate the LED in a drawer and verify that the MTMS corresponds to the drawer that requires the new adapter.
  • Identify LED for a FRU associated with a specified enclosure If you want to hook up a cable to a specific I/O adapter, you can activate the LED for the adapter which is a field replaceable unit (FRU), and then physically check to see where you should hook up the cable. This is especially useful when you have several adapters with open ports.

To activate or deactivate an identify LED for an enclosure or FRU, follow these steps:

  1. In the navigation area, open Systems Management.
  2. Select Servers.
  3. In the content area, check the box for the appropriate system.
  4. Select Tasks, then Operations, then LED Status, and then Identify LED.
  5. To activate or deactivate an identify LED for an enclosure, select an enclosure from the table, and click either Activate LED or Deactivate LED. The associated LED is either turned on or off.
  6. To activate or deactivate an identify LED for a FRU, select an enclosure from the table, select Selected > List FRUs.
  7. Select one or more FRUs from the table, and click either Activate LED or Deactivate LED. The associated LED is either turned on or off.