Use this information to help you map a location code to a position on the unit.
The following diagrams show the field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.








The following table provides location codes for parts that make up the server.
| Failing item name | Identify LED | Physical location code |
|---|---|---|
| System unit bulk power assembly (BPA) | Un | |
| Bulk power distribution (BPD) | ||
| Bulk power regulator (BPR) 4A, top | No | Un-P1–E1 |
| Bulk power regulator (BPR) 3A | No | Un-P1–E2 |
| Bulk power regulator (BPR) 2A | No | Un-P1–E3 |
| Bulk power regulator (BPR) 1A | No | Un-P1–E4 |
| Bulk power controller (BPC) A | No | Un-P1–C1 |
| Bulk power distribution (BPD) 1A | No | Un-P1–C2 |
| Bulk power distribution (BPD) 2A | No | Un-P1–C3 |
| Bulk power hub (BPH) A | No | Un-P1–C4 |
| Bulk power fan (BPF) A | No | Un-A1 |
| Bulk power assembly (BPA) B. Rear of frame, B side power boundary | Un-P2 | |
| Bulk power regulator (BPR) 4B, top | No | Un-P2–E1 |
| Bulk power regulator (BPR) 3B | No | Un-P2–E2 |
| Bulk power regulator (BPR) 2B | No | Un-P2–E3 |
| Bulk power regulator (BPR) 1B | No | Un-P2–E4 |
| Bulk power controller (BPC) B | No | Un-P2–C1 |
| Bulk power distribution (BPD) 1B | No | Un-P2–C2 |
| Bulk power distribution (BPD) 2B | No | Un-P2–C3 |
| Bulk power hub (BPH) B | No | Un-P2–C4 |
| Bulk power fan (BPF) B | No | Un-A2 |
| UEPO panel | Un-D1 | |
| Bulk power assembly (BPA) | ||
| BPR 4 | Un-Px-E1 | |
| Connector J01 | Un-Px-E1–J01 | |
| BPR 3 | Un-Px-E2 | |
| Connector J01 | Un-Px-E2–J01 | |
| BPR 2 | Un-Px-E3 | |
| Connector J01, IBF | Un-Px-E3–J01 | |
| BPR 1 | Un-Px-E4 | |
| Connector J01, IBF | Un-Px-E4–J01 | |
| Bulk power controller (BPC) | Un-Px-C1 | |
| Connector J01, BPC cross communication | No | Un-Px-C1–J01 |
| Connector J02, ethernet to BPH | No | Un-Px-C1–J02 |
| Connector J03, ethernet to BPH | No | Un-Px-C1–J03 |
| Connector J04, UEPO panel | No | Un-Px-C1–J04 |
| Connector J06, BPF | No | Un-Px-C1–J06 |
| Connector J07, BPC cross power | No | Un-Px-C1–J07 |
| Connector J10, MDA 1 & 3, Y cable powers 2 MDAs | No | Un-Px-C1–J10 |
| Connector J11, MDA 2 & 4, Y cable powers 2 MDAs | No | Un-Px-C1–J11 |
| Bulk power distribution (BPD) connectors | ||
| BPD1 | No | Un-Px-C2 |
| Connector J01, I/O drawer 1, DCA 2 | No | Un-Px-C2–J01 |
| Connector J02, I/O drawer 1, DCA 1 | No | Un-Px-C2–J02 |
| Connector J03, I/O drawer 2, DCA 2 | No | Un-Px-C2–J03 |
| Connector J04, I/O drawer 2, DCA 1 | No | Un-Px-C2–J04 |
| Connector J05, I/O drawer 3, DCA 2 | No | Un-Px-C2–J05 |
| Connector J06, I/O drawer 3, DCA 1 | No | Un-Px-C2–J06 |
| Connector J07, node P5 | No | Un-Px-C2–J07 |
| Connector J08, node P9 | No | Un-Px-C2–J08 |
| Connector J09, node P2 | No | Un-Px-C2–J09 |
| Connector J10, node P6 | No | Un-Px-C2–J10 |
| BPD2 | No | Un-Px-C3 |
| Connector J01, I/O drawer 4, DCA 2 | No | Un-Px-C3–J01 |
| Connector J02, I/O drawer 4, DCA 1 | No | Un-Px-C3–J02 |
| Connector J03, I/O drawer 5, DCA 2 | No | Un-Px-C3–J03 |
| Connector J04, I/O drawer 5, DCA 1 | No | Un-Px-C3–J04 |
| Connector J05, I/O drawer 6, DCA 2 | No | Un-Px-C3–J05 |
| Connector J06, I/O drawer 6, DCA 1 | No | Un-Px-C3–J06 |
| Connector J07, node P4 or I/O drawer 7 | No | Un-Px-C3–J07 |
| Connector J08, node P3 or I/O drawer 8 | No | Un-Px-C3–J08 |
| Connector J09, node P8 or I/O drawer 9 | No | Un-Px-C3–J09 |
| Connector J10, node P7 or I/O drawer 10 | No | Un-Px-C3–J10 |
| Bulk power hub (BPH) | No | Un-Px-C4 |
| Connector J01–J24 | No | Un-Px-C4–Jxx |
| UEPO panel | Un-Px-D1 | |
| Connector J01, to BPC-A | Un-Px-D1–J01 | |
| Connector J02, to BPC-B | Un-Px-D1–J02 | |
| Central electronics complex (CEC) | ||
| Midplane | Un-P1 | |
| Anchor card | Yes | Un-P1–C1 |
| FSP card 0 | Yes | Un-P1–C2 |
| Clock card 0 | Yes | Un-P1–C3 |
| Clock card 1 | Yes | Un-P1–C4 |
| FSP card 1 | Yes | Un-P1–C5 |
| Processor book 0, plugs into midplane | Yes | Un-P2 |
| Processor book 1 | Yes | Un-P6 |
| Processor book 2 | Yes | Un-P3 |
| Processor book 3 | Yes | Un-P7 |
| Processor book 4 | Yes | Un-P4 |
| Processor book 5 | Yes | Un-P8 |
| Processor book 6 | Yes | Un-P5 |
| Processor book 7 | Yes | Un-P9 |
| Air moving device AMD 1 | Yes | Un-A1 |
| Motor drive assembly (MDA) MDA 1 | Yes | Un-A1–E1 |
| Air moving device AMD 2 | Yes | Un-A2 |
| MDA 2 | Yes | Un-A2–E1 |
| Air moving device AMD 3 | Yes | Un-A3 |
| MDA 3 | Yes | Un-A3–E1 |
| Air moving device AMD 4 | Yes | Un-A4 |
| MDA 4 | Yes | Un-A4–E1 |
| Processor book Where m varies from 2–9 | ||
| DCA 1 | Yes | Un-Pm-E2 |
| DCA 2 | Yes | Un-Pm-E1 |
| I/O hub cards Where m varies from 2–9 | ||
| Slot T | Yes | Un-Pm-C40 |
| Slot S | Yes | Un-Pm-C39 |
| Slot U | Yes | Un-Pm-C38 |
| Slot V | Yes | Un-Pm-C37 |
| I/O hub card connectors Where m varies from 2–9 | ||
| Slot T | Yes | Un-Pm-C40–T01 and Un-Pm-C40–T02 |
| Slot S | Yes | Un-Pm-C39–T01 and Un-Pm-C39–T02 |
| Slot U | Yes | Un-Pm-C38–T01 and Un-Pm-C38–T02 |
| Slot V | Yes | Un-Pm-C37–T01 and Un-Pm-C37–T02 |
| Book FSP card 1 | Un-Pm-C42 | |
| Book FSP card 0 | Un-Pm-C41 | |
| FSP card connector J01 | Un-Pm-Cx-T01 | |
| FSP card connector J02 | Un-Pm-Cx-T02 | |
| Memory Where m varies from 2–9 | ||
| DIMM S1 | Yes | Un-Pm-C36 |
| DIMM S2 | Yes | Un-Pm-C35 |
| DIMM S3 | Yes | Un-Pm-C34 |
| DIMM S4 | Yes | Un-Pm-C33 |
| DIMM S5 | Yes | Un-Pm-C32 |
| DIMM S6 | Yes | Un-Pm-C31 |
| DIMM S7 | Yes | Un-Pm-C30 |
| DIMM S8 | Yes | Un-Pm-C29 |
| DIMM T1 | Yes | Un-Pm-C24 |
| DIMM T2 | Yes | Un-Pm-C23 |
| DIMM T3 | Yes | Un-Pm-C22 |
| DIMM T4 | Yes | Un-Pm-C21 |
| DIMM T5 | Yes | Un-Pm-C20 |
| DIMM T6 | Yes | Un-Pm-C19 |
| DIMM T7 | Yes | Un-Pm-C18 |
| DIMM T8 | Yes | Un-Pm-C17 |
| DIMM V1 | Yes | Un-Pm-C16 |
| DIMM V2 | Yes | Un-Pm-C15 |
| DIMM V3 | Yes | Un-Pm-C14 |
| DIMM V4 | Yes | Un-Pm-C13 |
| DIMM V5 | Yes | Un-Pm-C12 |
| DIMM V6 | Yes | Un-Pm-C11 |
| DIMM V7 | Yes | Un-Pm-C10 |
| DIMM V8 | Yes | Un-Pm-C9 |
| DIMM U1 | Yes | Un-Pm-C8 |
| DIMM U2 | Yes | Un-Pm-C7 |
| DIMM U3 | Yes | Un-Pm-C6 |
| DIMM U4 | Yes | Un-Pm-C5 |
| DIMM U5 | Yes | Un-Pm-C4 |
| DIMM U6 | Yes | Un-Pm-C3 |
| DIMM U7 | Yes | Un-Pm-C2 |
| DIMM U8 | Yes | Un-Pm-C1 |
| MCM-S | Un-Pm-C28 | |
| MCM-T | Un-Pm-C26 | |
| MCM-U | Un-Pm-C25 | |
| MCM-V | Un-Pm-C27 | |
| Front light strip | Yes | Un-P10 |
| Back light strip | Yes | Un-P11 |
| Central electronics
complex (CEC) cage connectors System controller 0, 1 Where m is 2 or 5 |
||
| Connector J1, front light strip (J01 or J02) | No | Un-P1–Cm-T1 |
| Connector J2, back light strip (J01 or J02) | No | Un-P1–Cm-T2 |
| Connector J3, ethernet connects to BHP A | Yes | Un-P1–Cm-T3 |
| Connector J4Ethernet connects to BHP B | Yes | Un-P1–Cm-T4 |
| Connector J5, SPCN connector | No | Un-P1–Cm-T5 |
| Book connectors | ||
| Super UPIC power connector J01 | No | Un-Px-J01 |
| Super UPIC power connector J02 | No | Un-Px-J02 |
| Motor drive assembly (MDA) MDA 1 | Yes | Un-A2–E1 |
| MDA 2 | Yes | Un-A4–E1 |
| MDA 3 | Yes | Un-A3–E1 |
| MDA 4 | Yes | Un-A1–E1 |
| Device physical locations | ||
| Disk drive 1 | Un-P3-D01 (logical location P2-T6-L8-L0) | |
| Disk drive 2 | Un-P3-D02 (logical location P2-T6-L9-L0) | |
| Disk drive 3 | Un-P3-D03 (logical location P2-T6-L10-L0) | |
| Disk drive 4 | Un-P3-D04 (logical location P2-T6-L11-L0) | |
| Disk drive 5 | Un-P4-D05 (logical location P2-T5-L8-L0) | |
| Disk drive 6 | Un-P4-D06 (logical location P2-T5-L9-L0) | |
| Disk drive 7 | Un-P4-D07 (logical location P2-T5-L10-L0) | |
| Disk drive 8 | Un-P4-D08 (logical location P2-T5-L11-L0) | |
| Disk drive 9 | Un-P5-D09 (logical location P1-T6-L8-L0) | |
| Disk drive 10 | Un-P5-D10 (logical location P1-T6-L9-L0) | |
| Disk drive 11 | Un-P5-D11 (logical location P1-T6-L10-L0) | |
| Disk drive 12 | Un-P5-D12 (logical location P1-T6-L11-L0) | |
| Disk drive 13 | Un-P6-D13 (logical location P1-T5-L8-L0) | |
| Disk drive 14 | Un-P6-D14 (logical location P1-T5-L9-L0) | |
| Disk drive 15 | Un-P6-D15 (logical location P1-T5-L10-L0) | |
| Disk drive 16 | Un-P6-D16 (logical location P1-T5-L11-L0) | |
| Multi-adapter bridge domain / PCI bridge set | IOA assignment rules |
|---|---|
| P1-C01 through P1-C04 | P1-C02, P1-C03, P1-C04 |
| P1-C05 through P1-C07 | P1-C06, P1-C07 |
| P2-C01 through P2-C04 | P2-C02, P2-C03, P2-C04 |
| P2-C05 through P2-C07 | P2-C06, P2-C07 |