Locations

Use this information to help you map a location code to a position on the unit.

Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.

The following diagrams show the field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.

Figure 1. Front and rear views
Front and rear views
Figure 2. Emergency power off (EPO)
Emergency power off (EPO).
Figure 3. Light strip views
Light strip views
Figure 4. Bulk power assembly (BPA). Front is Un-P1 and back is Un-P2.
Bulk power assembly (BPA).
Figure 5. Light strip views
Light strip views
Figure 6. Node locations
Node locations
Figure 7. I/O hub card locations (top nodes)
I/O hub card locations (top nodes)
Figure 8. I/O hub card locations (bottom nodes)
I/O hub card locations (bottom nodes)

The following table provides location codes for parts that make up the server.

Table 1. Bulk power assembly (BPA) locations, and failing components
Failing item name Identify LED Physical location code
System unit bulk power assembly (BPA)   Un
Bulk power distribution (BPD)
Bulk power regulator (BPR) 4A, top No Un-P1–E1
Bulk power regulator (BPR) 3A No Un-P1–E2
Bulk power regulator (BPR) 2A No Un-P1–E3
Bulk power regulator (BPR) 1A No Un-P1–E4
Bulk power controller (BPC) A No Un-P1–C1
Bulk power distribution (BPD) 1A No Un-P1–C2
Bulk power distribution (BPD) 2A No Un-P1–C3
Bulk power hub (BPH) A No Un-P1–C4
Bulk power fan (BPF) A No Un-A1
Bulk power assembly (BPA) B. Rear of frame, B side power boundary   Un-P2
Bulk power regulator (BPR) 4B, top No Un-P2–E1
Bulk power regulator (BPR) 3B No Un-P2–E2
Bulk power regulator (BPR) 2B No Un-P2–E3
Bulk power regulator (BPR) 1B No Un-P2–E4
Bulk power controller (BPC) B No Un-P2–C1
Bulk power distribution (BPD) 1B No Un-P2–C2
Bulk power distribution (BPD) 2B No Un-P2–C3
Bulk power hub (BPH) B No Un-P2–C4
Bulk power fan (BPF) B No Un-A2
UEPO panel   Un-D1
Bulk power assembly (BPA)
BPR 4   Un-Px-E1
Connector J01   Un-Px-E1–J01
BPR 3   Un-Px-E2
Connector J01   Un-Px-E2–J01
BPR 2   Un-Px-E3
Connector J01, IBF   Un-Px-E3–J01
BPR 1   Un-Px-E4
Connector J01, IBF   Un-Px-E4–J01
Bulk power controller (BPC)   Un-Px-C1
Connector J01, BPC cross communication No Un-Px-C1–J01
Connector J02, ethernet to BPH No Un-Px-C1–J02
Connector J03, ethernet to BPH No Un-Px-C1–J03
Connector J04, UEPO panel No Un-Px-C1–J04
Connector J06, BPF No Un-Px-C1–J06
Connector J07, BPC cross power No Un-Px-C1–J07
Connector J10, MDA 1 & 3, Y cable powers 2 MDAs No Un-Px-C1–J10
Connector J11, MDA 2 & 4, Y cable powers 2 MDAs No Un-Px-C1–J11
Bulk power distribution (BPD) connectors
BPD1 No Un-Px-C2
Connector J01, I/O drawer 1, DCA 2 No Un-Px-C2–J01
Connector J02, I/O drawer 1, DCA 1 No Un-Px-C2–J02
Connector J03, I/O drawer 2, DCA 2 No Un-Px-C2–J03
Connector J04, I/O drawer 2, DCA 1 No Un-Px-C2–J04
Connector J05, I/O drawer 3, DCA 2 No Un-Px-C2–J05
Connector J06, I/O drawer 3, DCA 1 No Un-Px-C2–J06
Connector J07, node P5 No Un-Px-C2–J07
Connector J08, node P9 No Un-Px-C2–J08
Connector J09, node P2 No Un-Px-C2–J09
Connector J10, node P6 No Un-Px-C2–J10
BPD2 No Un-Px-C3
Connector J01, I/O drawer 4, DCA 2 No Un-Px-C3–J01
Connector J02, I/O drawer 4, DCA 1 No Un-Px-C3–J02
Connector J03, I/O drawer 5, DCA 2 No Un-Px-C3–J03
Connector J04, I/O drawer 5, DCA 1 No Un-Px-C3–J04
Connector J05, I/O drawer 6, DCA 2 No Un-Px-C3–J05
Connector J06, I/O drawer 6, DCA 1 No Un-Px-C3–J06
Connector J07, node P4 or I/O drawer 7 No Un-Px-C3–J07
Connector J08, node P3 or I/O drawer 8 No Un-Px-C3–J08
Connector J09, node P8 or I/O drawer 9 No Un-Px-C3–J09
Connector J10, node P7 or I/O drawer 10 No Un-Px-C3–J10
Bulk power hub (BPH) No Un-Px-C4
Connector J01–J24 No Un-Px-C4–Jxx
UEPO panel   Un-Px-D1
Connector J01, to BPC-A   Un-Px-D1–J01
Connector J02, to BPC-B   Un-Px-D1–J02
Central electronics complex (CEC)
Midplane   Un-P1
Anchor card Yes Un-P1–C1
FSP card 0 Yes Un-P1–C2
Clock card 0 Yes Un-P1–C3
Clock card 1 Yes Un-P1–C4
FSP card 1 Yes Un-P1–C5
Processor book 0, plugs into midplane Yes Un-P2
Processor book 1 Yes Un-P6
Processor book 2 Yes Un-P3
Processor book 3 Yes Un-P7
Processor book 4 Yes Un-P4
Processor book 5 Yes Un-P8
Processor book 6 Yes Un-P5
Processor book 7 Yes Un-P9
Air moving device AMD 1 Yes Un-A1
Motor drive assembly (MDA) MDA 1 Yes Un-A1–E1
Air moving device AMD 2 Yes Un-A2
MDA 2 Yes Un-A2–E1
Air moving device AMD 3 Yes Un-A3
MDA 3 Yes Un-A3–E1
Air moving device AMD 4 Yes Un-A4
MDA 4 Yes Un-A4–E1
Processor book Where m varies from 2–9
DCA 1 Yes Un-Pm-E2
DCA 2 Yes Un-Pm-E1
I/O hub cards Where m varies from 2–9
Slot T Yes Un-Pm-C40
Slot S Yes Un-Pm-C39
Slot U Yes Un-Pm-C38
Slot V Yes Un-Pm-C37
I/O hub card connectors Where m varies from 2–9
Slot T Yes Un-Pm-C40–T01 and Un-Pm-C40–T02
Slot S Yes Un-Pm-C39–T01 and Un-Pm-C39–T02
Slot U Yes Un-Pm-C38–T01 and Un-Pm-C38–T02
Slot V Yes Un-Pm-C37–T01 and Un-Pm-C37–T02
Book FSP card 1   Un-Pm-C42
Book FSP card 0   Un-Pm-C41
FSP card connector J01   Un-Pm-Cx-T01
FSP card connector J02   Un-Pm-Cx-T02
Memory Where m varies from 2–9
DIMM S1 Yes Un-Pm-C36
DIMM S2 Yes Un-Pm-C35
DIMM S3 Yes Un-Pm-C34
DIMM S4 Yes Un-Pm-C33
DIMM S5 Yes Un-Pm-C32
DIMM S6 Yes Un-Pm-C31
DIMM S7 Yes Un-Pm-C30
DIMM S8 Yes Un-Pm-C29
DIMM T1 Yes Un-Pm-C24
DIMM T2 Yes Un-Pm-C23
DIMM T3 Yes Un-Pm-C22
DIMM T4 Yes Un-Pm-C21
DIMM T5 Yes Un-Pm-C20
DIMM T6 Yes Un-Pm-C19
DIMM T7 Yes Un-Pm-C18
DIMM T8 Yes Un-Pm-C17
DIMM V1 Yes Un-Pm-C16
DIMM V2 Yes Un-Pm-C15
DIMM V3 Yes Un-Pm-C14
DIMM V4 Yes Un-Pm-C13
DIMM V5 Yes Un-Pm-C12
DIMM V6 Yes Un-Pm-C11
DIMM V7 Yes Un-Pm-C10
DIMM V8 Yes Un-Pm-C9
DIMM U1 Yes Un-Pm-C8
DIMM U2 Yes Un-Pm-C7
DIMM U3 Yes Un-Pm-C6
DIMM U4 Yes Un-Pm-C5
DIMM U5 Yes Un-Pm-C4
DIMM U6 Yes Un-Pm-C3
DIMM U7 Yes Un-Pm-C2
DIMM U8 Yes Un-Pm-C1
MCM-S   Un-Pm-C28
MCM-T   Un-Pm-C26
MCM-U   Un-Pm-C25
MCM-V   Un-Pm-C27
Front light strip Yes Un-P10
Back light strip Yes Un-P11
Central electronics complex (CEC) cage connectors
System controller 0, 1 Where m is 2 or 5
Connector J1, front light strip (J01 or J02) No Un-P1–Cm-T1
Connector J2, back light strip (J01 or J02) No Un-P1–Cm-T2
Connector J3, ethernet connects to BHP A Yes Un-P1–Cm-T3
Connector J4Ethernet connects to BHP B Yes Un-P1–Cm-T4
Connector J5, SPCN connector No Un-P1–Cm-T5
Book connectors
Super UPIC power connector J01 No Un-Px-J01
Super UPIC power connector J02 No Un-Px-J02
Motor drive assembly (MDA) MDA 1 Yes Un-A2–E1
MDA 2 Yes Un-A4–E1
MDA 3 Yes Un-A3–E1
MDA 4 Yes Un-A1–E1
Device physical locations
Disk drive 1   Un-P3-D01 (logical location P2-T6-L8-L0)
Disk drive 2   Un-P3-D02 (logical location P2-T6-L9-L0)
Disk drive 3   Un-P3-D03 (logical location P2-T6-L10-L0)
Disk drive 4   Un-P3-D04 (logical location P2-T6-L11-L0)
Disk drive 5   Un-P4-D05 (logical location P2-T5-L8-L0)
Disk drive 6   Un-P4-D06 (logical location P2-T5-L9-L0)
Disk drive 7   Un-P4-D07 (logical location P2-T5-L10-L0)
Disk drive 8   Un-P4-D08 (logical location P2-T5-L11-L0)
Disk drive 9   Un-P5-D09 (logical location P1-T6-L8-L0)
Disk drive 10   Un-P5-D10 (logical location P1-T6-L9-L0)
Disk drive 11   Un-P5-D11 (logical location P1-T6-L10-L0)
Disk drive 12   Un-P5-D12 (logical location P1-T6-L11-L0)
Disk drive 13   Un-P6-D13 (logical location P1-T5-L8-L0)
Disk drive 14   Un-P6-D14 (logical location P1-T5-L9-L0)
Disk drive 15   Un-P6-D15 (logical location P1-T5-L10-L0)
Disk drive 16   Un-P6-D16 (logical location P1-T5-L11-L0)
Note:
  1. The following table provides information necessary to identify the IOP to which an IOA is assigned.
    • The left column indicates the domain in which IOA assignment is allowed.
    • The right column is used to determine the IOP to which an IOA is assigned.
    • The first position in the list must be an IOP. The remaining positions may be IOPs or IOAs. IOAs are assigned to the first IOP located to their left in the list. Although IOAs can be manually reassigned using SST/DST, the IOA assignments return to the default order after each IPL.
      Table 2. Identify the IOP to which IOAs are assigned
      Multi-adapter bridge domain / PCI bridge set IOA assignment rules
      P1-C01 through P1-C04 P1-C02, P1-C03, P1-C04
      P1-C05 through P1-C07 P1-C06, P1-C07
      P2-C01 through P2-C04 P2-C02, P2-C03, P2-C04
      P2-C05 through P2-C07 P2-C06, P2-C07