You might need to replace the service processor cable from the server. Use the procedure in this section to perform this task.

For assistance, use the following tables as a guide:
| Service processor ports | One SP and one HMC | One SP and two HMCs | Two SP and one HMC | Two SP and two HMCs |
|---|---|---|---|---|
| T1 (HMC) | to HMC #1 from hub #1*** | to HMC #1 from hub #1 | to HMC #1 from hub #1 | to HMC #1 from hub #1 |
| T2 (HMC) | to HMC #2 from hub #1 | jumper to SP#2 T2 | to HMC #2 from hub #2 | |
| T3 (SPCN) | to first I/O device* | to first I/O device* | to first I/O device* | to first I/O device* |
| T4 (SPCN) | to last I/O device** | to last I/O device** | jumper to SP#2 T3 | jumper to SP#2 T3 |
| Service processor ports | One service processor and one HMC | One service processor and two HMCs | Two service processor and one HMC | Two service processor and two HMCs |
|---|---|---|---|---|
| T1 (HMC) | to HMC #1 from hub #1 | to HMC #1 from hub #1 | ||
| T2 (HMC) | jumper to SP#1 T2 | to HMC #2 from hub #2 | ||
| T3 (SPCN) | jumper to SP#1 T4 | jumper to SP#1 T4 | ||
| T4 (SPCN) | to last I/O device** | to last I/O device** |
** Last I/O system in a single loop configuration with jumpered links.
*** The Ethernet hub is optional. You can choose to connect the service processor directly to the HMC.