5075 PCI expansion entry tower

Hardware specifications provide detailed information for your expansion unit, including dimensions, electrical, power, temperature, environment, and service clearances.

Table 1. Hardware specifications

Pictured is the 5075 PCI expansion entry tower.

Dimensions are shown for the 5075 PCI expansion entry tower only.

5075
Dimensions Width Depth Height
Metric 330 mm 690 mm 560 mm
English 12.9 in. 27.1 in. 22.0 in.
Maximum configuration weight 52.7 kg (116 lb.)
Electrical
kVA (maximum) 0.316
Rated voltage and frequency 100-127/200-240 V ac at 50-60 plus or minus 0.5 Hz
Thermal output (maximum) 1024 Btu/hr
Power requirements (maximum) 300 W
Power factor 0.95
Inrush current 74 A
Leakage current (maximum) 3.5 mA
Phase 1
Plug type (Canada and U.S.) 4, 5, 10, or 34
Power cord length 1.8 m (6 ft.) (U.S. only), 4.3 m (14 ft.)
Temperature requirements
Operating 10 degrees to 38 degrees C (50 degrees to 100.4 degrees F)
Nonoperating 1 degrees to 60 degrees C (33.8 degrees to 140 degrees F)
Environment requirements Operating Nonoperating
Noncondensing Humidity 8 to 80% 8 to 80%
Wet bulb temperature 23 degrees C (73.4 degrees F) 27 degrees C (80.6 degrees F)
Maximum altitude 3048 m (10000 ft.)
Noise emissions1 Operating Idle
LWAd 6.0 bels 5.7 bels
LpAm (1-meter bystander) 42 dB 39 dB
Service clearances
Front Back Sides2 Top2
762 mm 762 mm 762 mm 762 mm
30 in. 30 in. 30 in. 30 in.

Notes:

  1. For a description of noise emission values, see the Acoustics chapter of the Site Preparation and Physical Planning Guide, SA76-0103.
  2. Side and top clearances are optional when operating.