| E302Exxx |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F000 to E302F7xx |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F800 |
An error occurred while attempting to create a provider
instance of the service processor interface code as a PIHSCCECCIMClient.
An exception was thrown from the PIHSCCECCIMClient createInstance code.
Go to the Server and Partition display, refresh the screen and ensure the
system is in a good state (for example, power off, standby, or operating).
Then repeat the operation. |
|
| E302F801 |
An error occurred while attempting to find one of the
directories used to store data for the firmware update application.
Reboot
the HMC and try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F802 |
The survey from the repository method was called, but
the repository selected was not the IBM® support system, the IBM Web site, the DVD, or the hard drive.
Use the HMC graphical user interface (GUI) to reselect the source for
code updates, then retry the update. If the problem occurs again, contact
your next level of support. |
|
| E302F803 |
The survey from an FTP site failed when downloading the
list of files from the FTP repository failed.
Verify that you correctly
entered valid values for the FTP site, user, password, and directory. Then
repeat the operation. |
|
| E302F804 |
The request to get a list of IBM support system
fixpacks failed because the request
timed out.
Verify that the HMC is properly configured to communicate
with the IBM support system. Verify that the IBM support system has accepted the administrative information for your HMC,
then repeat the operation.
Verify that you correctly entered valid values
for the FTP site, user, password, and directory. Then repeat the operation. |
|
| E302F805 |
The request to get a list of IBM support system
fixpacks failed with an exception.
Repeat the operation. If it fails, call your next level of support. |
|
| E302F806 |
The request to get a list of IBM support system
fixpacks failed with an error code.
Repeat the operation. If it fails, call your next level of support. |
|
| E302F807 |
No phone server was available to service the request to
get a list of IBM support system fixpacks.
Ensure that your connection to the IBM support system is set up correctly and repeat the operation. |
|
| E302F808 |
The list of fixpacks was retrieved from the IBM support
system, but an I/O exception occurred when the list was written to the hard
file.
Reboot the HMC and retry the operation. If it fails again, consider
replacing the disk drive in the HMC. |
|
| E302F809 |
An error occurred while attempting to run the code to
get the service processor to run a query, or set, the current IPL side or
the next IPL side.
Go to the Server and Partition display, refresh the screen
and ensure the system is in a good state (for example, power off, standby,
or operating). Then repeat the operation. |
|
| E302F80A |
An invalid object was used while attempting to create
an owner for the update.
Something is wrong with the selected target. Reboot
the HMC and retry the operation. If the problem persists contact your
next level of support. |
|
| E302F80B |
Unable to get the name of the HMC while preparing
to create a service processor client.
Reboot the HMC and retry the operation.
If it fails again, contact your next level of support. |
|
| E302F80C |
Failure when attempting to read a file.
Reboot the HMC
and retry the operation. If it fails again, consider replacing the disk drive
of the HMC. |
|
| E302F80D |
Failure when attempting to close a file.
Reboot the HMC
and retry the operation. If it fails again, consider replacing the disk drive
of the HMC. |
|
| E302F80E |
The list of fixpacks was retrieved from
the IBM support
system, but an I/O exception occurred when closing the list that was written
to the hard file.
Reboot the HMC and retry the operation. If it fails
again, consider replacing the disk drive of the HMC. |
|
| E302F80F |
The method to import the stageable cover letter was called,
but the repository selected was not the IBM support system,
the IBM Web site,, the DVD, or the hard drive.
Use the HMC GUI to reselect the source
for code updates, and then retry the update. If the problem occurs again,
contact your next level of support. |
|
| E302F810 |
Unable to FTP the cover letter from the specified repository
to the staging area.
Verify that the FTP site is still up, and then retry
the operation. |
|
| E302F811 |
The request to get cover letter from the IBM support
system timed out.
Verify
that your connection to the IBM support system is set up correctly
and is operational. Retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F812 |
The request to get cover letter from the IBM support
system failed with an exception.
Verify that your connection to the IBM support system is set up correctly
and is operational. Retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F813 |
The request to get cover letter from the IBM support
system failed with an error
code.
Verify that your connection to the IBM support
system is set up correctly and is operational. Retry the operation. If the
problem occurs again, contact your next level of support. |
|
| E302F814 |
No phone server was available to service the request to
get cover letters from the IBM support system.
Configure the HMC as a phone server and retry the
operation. |
|
| E302F815 |
Failure when attempting to copy the cover
letter from the DVD to the staging area
on the hard file.
The CD or DVD may be faulty. Try another one. |
|
| E302F816 |
An error occurred when attempting to get the service processor
to run a query of its state.
Go to the Server and Partition display, refresh
the screen and ensure the system is in a good state (for example, power off,
standby, or operating). Then repeat the operation. |
|
| E302F817 |
A query of the current IPL side returned a null.
Go
to the Server and Partition display, refresh the screen and ensure the system
is in a good state (for example, power off, standby, or operating). Then repeat
the operation. |
|
| E302F818 |
A query of the next IPL side returned a null.
Go to
the Server and Partition display, refresh the screen and ensure the system
is in a good state (for example, power off, standby, or operating). Then repeat
the operation. |
|
| E302F819 |
A query of the current IPL side failed.
Go to the Server
and Partition display, refresh the screen and ensure the system is in a good
state (for example, power off, standby, or operating). Then repeat the operation. |
|
| E302F81A |
An exception occurred during a query of the current IPL
side.
Go to the Server and Partition display, refresh the screen and ensure
the system is in a good state (for example, power off, standby, or operating).
Then repeat the operation. |
|
| E302F81B |
A query of the next IPL side failed.
Go to the Server
and Partition display, refresh the screen and ensure the system is in a good
state (for example, power off, standby, or operating). Then repeat the operation. |
|
| E302F81C |
An exception occurred during a query of the next IPL side.
Go to the Server and Partition display, refresh the screen and ensure the
system is in a good state (for example, power off, standby, or operating).
Then repeat the operation. |
|
| E302F81D |
Failure during an attempt to copy the cover letter from the IBM Web
site to the staging area on the hard file.
Reboot the HMC. Verify that
your LAN connection is set up properly. Then retry the operation. |
|
| E302F81E |
Failure of a survey from an FTP site occurred when
a connection to the site was unavailable.
Ensure that the FTP site is reachable
on the network from the HMC and that the site is up and running properly.
Ensure that all firewall authentications are successfully performed if needed,
and then retry the operation. |
|
| E302F81F |
Failure of a survey from an FTP site occurred when
logging into the site was unsuccessful.
Ensure that the login parameters
are correct, and then retry the operation. |
|
| E302F820 |
An error occurred while attempting to read the common
marker firmware update file from flash memory to the hard file.
Go to the
Server and Partition display, refresh the screen and ensure the system is
in a good state (for example, power off, standby, or operating). Then repeat
the operation. If the problem occurs again contact your next level of support. |
|
| E302F821 |
An error occurred while attempting to read the common
marker firmware update file from the hard file into memory.
Reboot the HMC
and retry the operation. If the problem occurs again contact your next level
of support. |
|
| E302F822 |
An error occurred while attempting to find one of the
directories used to store data for the firmware update application.
Reboot
the HMC and try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F823 to E302F827 |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F828 |
An error occurred while attempting to read the master
firmware update file from flash memory to the hard drive.
Reboot the HMC
and try the operation again. If the problem occurs again, contact your next
level of support. |
|
| E302F829 |
An error occurred while attempting to read the master
firmware update file from the hard drive into memory.
Reboot the HMC
and try the operation again. If the problem occurs again, contact your next
level of support. |
|
| E302F82A |
An error occurred while attempting to read the header
of the master firmware update file from flash memory to the hard file.
Reboot the HMC and try the operation again. If the problem occurs again,
contact your next level of support. |
|
| E302F82B |
An error occurred while attempting to find one of the
directories used to store data for the firmware update application.
Reboot
the HMC and try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F82C |
An error occurred while attempting to create a provider
instance of the secondary service processor interface code as a PIHSCCECCIMClient.
An exception was thrown from the PIHSCCECCIMClient createInstance code.
Go to the Server and Partition display, refresh the screen and ensure that
the system is in a good state (power off, standby, or power on). Then repeat
the operation. |
|
| E302F82D |
This error code will be posted
under either of the following set of conditions:
Action: Install the latest HMC code package, then install
the latest system firmware. |
| E302F82E, E302F82F |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F830 |
An error occurred while attempting to read a flash firmware
update file from the hard file into memory.
Reboot the HMC and try the
operation again. If the problem occurs again, consider replacing the disk
drive of the HMC. |
|
| E302F831 |
A file that was supposed to be a firmware update file
either does not exist or is too small to contain a valid header.
If you
are using nondisruptive microcode, verify that your test firmware update files
are correct. Otherwise contact your next level of support. |
|
| E302F832 |
An error occurred while trying to create a private
staging area directory for firmware update files on the HMC disk drive.
Follow the HMC procedures to remove dump files from the HMC disk drive.
(The HMC disk drive is used for the private staging area and it may be
full.) Then reboot the HMC and try the operation again. If the problem
occurs again, contact your next level of support. |
|
| E302F833 |
An error occurred while trying to change file permissions
in the private staging area directory for firmware update files.
This error
might indicate that the files in the private staging area were not created,
especially if this error occurs with E302F832. Follow the procedures for E302F832. |
|
| E302F834 to E302F837 |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F838 |
An error occurred while attempting to read the information
about the fixpack out
of the cover letter.
Verify that the cover letter is correct and has not
been corrupted. Reboot the HMC and try the operation again. If the problem
occurs again, contact your next level of support. |
|
| E302F839 to E302F83F |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F840 |
An error occurred while attempting to get the engineering
change streams in order to retrieve all of the updates from removable media.
Reboot the HMC and try the operation again. If the problem occurs again,
contact your next level of support. |
|
| E302F841 |
An error occurred while attempting to issue a start code
update command to the master service processor.
Try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F842 |
An error occurred while attempting to issue a write firmware
update file command to the master service processor.
Try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F843 |
An error occurred while attempting to issue a "code update
complete" action to the master service processor.
Try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F844 |
An error occurred while attempting to reboot the service
processor
Try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F845 |
The "import from a remote repository" code routine was
called, but the repository selected was not the IBM support system
or the IBM Web site.
Use the HMC GUI to reselect the source for code updates. If the
problem occurs again, contact your next level of support. |
|
| E302F846 |
An error occurred while attempting to swap the T and P
sides of the service processor.
Try the operation again. If the problem
occurs again, contact your next level of support. |
|
| E302F847 |
An engineering change stream was passed between components,
but no such engineering change stream exists for the targeted object.
Reboot
the HMC and try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F848 |
A request to import the IBM support system
fixpacks and cover letters timed out.
Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation.
If the problem reoccurs, contact your next level of support. |
|
| E302F849 |
A request to import the IBM support system
fixpacks and cover letters failed.
Verify that your connection to the IBM support
system is set up correctly and is operational. Retry the operation. If the
problem reoccurs, contact your next level of support. |
|
| E302F84A |
Failure during an attempt to read the surveyed list of fixpacks.
Reboot the HMC
and try the operation again. If the problem occurs again, consider replacing
the disk drive of your HMC. |
|
| E302F84B |
Failure during an attempt to close the surveyed list of fixpacks.
Reboot the HMC
and try the operation again. If the problem occurs again, consider replacing
the disk drive of your HMC. |
|
| E302F84C |
An error occurred while attempting to get the engineering
change streams in order to list all of the updates available on the removable
media.
Reboot the HMC and try the operation again. If the problem occurs
again, contact your next level of support. |
|
| E302F84D |
An error occurred while trying to copy the RPM files from
the media repository to the hard file.
The CD or DVD may be faulty. Try
another one. |
|
| E302F84E |
An error occurred in a removable media code routine because
the file types were null.
Reboot the HMC and try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F84F |
An error occurred in a method because one of the file
arrays had a length of zero.
Reboot the HMC and try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F850 |
A failure occurred while trying to unpack the RPM file
in the "complete concurrently" code routine.
Reboot the HMC and try
the operation again. In the HMC code released before August 2004, there
was a problem that can be corrected with commands from the Linux command
line as follows:
ls -l /opt/ccfw/data/*.rpm
rpm -qp rpmfilename
(where rpmfilename is the name of the file returned by the ls command)
rpm -e rpm packagename
(where packagename is the name of the package returned by the rpm -e command) |
|
| E302F851 |
The request to retrieve fixpacks from
the IBM support system failed
with an error code.
Verify that your connection to the IBM support system is set up correctly and is operational. Retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F852 |
No phone server was available to serve the request to
retrieve IBM support system fixpacks.
Configure the HMC as a phone server and retry the operation. |
|
| E302F853 |
An error occurred while attempting to find the directory
where firmware update files are stored for testing with the non disruptive
application panel.
Reboot the HMC and try the operation again. If the
problem occurs again, contact your next level of support. |
|
| E302F854 |
An error occurred while attempting to issue a read firmware
update file command to a service processor
Try the operation again. If the
problem occurs again, contact your next level of support. |
|
| E302F855 |
Importing from an FTP site failed when the files from
the FTP repository were not retrieved.
Try the operation again. If the problem
occurs again, contact your next level of support. |
|
| E302F856 |
A failure occurred when trying to query the name of the
image in the RPM file.
Try the operation again. If the problem occurs again,
contact your next level of support. |
|
| E302F857 |
A failure occurred while attempting to issue the runact
API.
Try the operation again. If the problem occurs again, contact your
next level of support. |
|
| E302F858 |
An exception occurred while attempting to issue the runact
API.
Try the operation again. If the problem occurs again, contact your
next level of support. |
|
| E302F859 |
An exception occurred while trying to query the name of
the image in the RPM file.
Try the operation again. If the problem occurs
again, contact your next level of support. |
|
| E302F85A |
An exception occurred while trying to unpack the RPM file
in the "complete concurrently" code routine.
Try the operation again. If
the problem occurs again, contact your next level of support. |
|
| E302F85B |
An exception occurred while trying to import updates from
the DVD.
The CD or DVD may be faulty. Try another one. |
|
| E302F85C |
An error occurred while attempting to copy the T side
to the P side.
In the Licensed Internal Code Update panels, choose Select advanced features, and then choose Accept to
copy the T side to the P side. If the problem occurs again, contact your
next level of support. |
|
| E302F85D |
An error occurred while attempting to IPL the system unit.
The level of code requested is most likely activated on the targeted system.
Verify the activated level through System Information. Then IPL the system
unit if desired. |
|
| E302F85E |
An error occurred while attempting to power on the system
unit.
The level of code requested is most likely activated on the targeted
system. Verify the activated level through System Information. Then power
on the system unit if desired. |
|
| E302F85F |
An error occurred while attempting to power off the system
unit.
Try powering off the system unit manually and doing the code update
while the system is in the platform standby state. |
|
| E302F860 |
An error occurred while trying to import updates to the
DVD during an export command.
The CD or DVD may be faulty. Try another one. |
|
| E302F861 |
An error occurred while attempting to open the hypervisor
diff file prior to writing.
The level of code requested is most likely activated
on the targeted system, but not loaded into the server firmware. Verify the
activated level through System Information. If the activated level is what
is expected, schedule a time to IPL the system. |
|
| E302F862 |
An error occurred while attempting to write the hypervisor
diff file to the hypervisor.
The level of code requested is most likely
activated on the targeted system, but not loaded into the server firmware.
Verify the activated level through System Information. If the activated level
is what is expected, schedule a time to IPL the system. |
|
| E302F863 |
An error occurred while attempting to close the hypervisor
firmware diff file after writing it to the server firmware.
The level of
code requested is most likely activated on the targeted system, but not loaded
into the hypervisor. Verify the activated level through System Information.
If the activated level is what is expected, schedule a time to IPL the system. |
|
| E302F864 |
An exception occurred during the query to see if a hypervisor
firmware update has completed.
The level of code requested is most likely
activated on the targeted system, but not loaded into the hypervisor. Verify
the activated level through System Information. If the activated level is
what is expected, schedule a time to IPL the system. |
|
| E302F865 |
A failure occurred while querying the status after a firmware
update.
The level of code requested is most likely activated on the targeted
system, but not loaded into the server firmware. Verify the activated level
through System Information. If the activated level is what is expected, schedule
a time to IPL the system. |
|
| E302F866 |
The hypervisor firmware update timed out.
The level
of code requested is most likely activated on the targeted system, but not
loaded into the hypervisor. Verify the activated level through System Information.
If the activated level is what is expected, schedule a time to IPL the system. |
|
| E302F867 |
An interruption occurred while waiting for the hypervisor
firmware update.
The level of code requested is most likely activated on
the targeted system, but not loaded into the hypervisor. Verify the activated
level through System Information. If the activated level is what is expected,
schedule a time to IPL the system. |
|
| E302F868 |
An error occurred while issuing a start code update command
to the secondary service processor.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F869 |
An error occurred while issuing a write firmware update
file command to the secondary service processor.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F86A |
An error occurred issuing a code update complete command
to the secondary service processor.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F86B |
A failure occurred while issuing a runact API to query
the partitions and their status.
The level of code requested is most likely
activated on the targeted system, but not loaded into the server firmware.
Verify the activated level through System Information. If the activated level
is what is expected, schedule a time to restart the partitions. |
|
| E302F86C |
An exception occurred while issuing a runact API to query
the partitions and their status.
The level of code requested is most likely
activated on the targeted system, but not loaded into the server firmware.
Verify the activated level through System Information. If the activated level
is what is expected, schedule a time to restart the partitions. |
|
| E302F86D |
A fixpack did not contain a diff firmware update file, or no diff firmware update
file was found in the firmware update file directory, for nondisruptive firmware
application.
The level of code requested is most likely activated on the
targeted system, but not loaded into the server firmware. Verify the activated
level through System Information. If the activated level is what is expected,
schedule a time to IPL the system. |
|
| E302F86E |
An error occurred during a call to a code module while
preparing to write the hypervisor firmware diff file to flash memory.
The
level of code requested is most likely activated on the targeted system, but
not loaded into the hypervisor firmware. Verify the activated level through
System Information. If the activated level is what is expected, schedule a
time to IPL the system. |
|
| E302F86F |
An error occurred during a call to a code module while
attempting to write the hypervisor firmware diff file to flash memory.
The level of code requested is most likely activated on the targeted system,
but not loaded into the hypervisor firmware. Verify the activated level through
System Information. If the activated level is what is expected, schedule a
time to IPL the system. |
|
| E302F870 |
An error occurred during a call to a code module after
writing the hypervisor firmware diff file to flash memory.
The level of
code requested is most likely activated on the targeted system, but not loaded
into the hypervisor firmware. Verify the activated level through System Information.
If the activated level is what is expected, schedule a time to IPL the system. |
|
| E302F871 |
An error occurred during the call to start firmware update
to concurrently patch firmware.
The level of code requested is most likely
activated on the targeted system, but not loaded into the server firmware.
Verify the activated level through System Information. If the activated level
is what is expected, schedule a time to IPL the system. |
|
| E302F872 |
Querying status after a firmware update did not return
the proper number of elements in the vector.
The level of code requested
is most likely activated on the targeted system, but not loaded into the server
firmware. Verify the activated level through System Information. If the activated
level is what is expected, schedule a time to IPL the system. |
|
| E302F873 |
Rebooting the service processor was executed, but the
system unit did not return to the state where the T side was active within
a reasonable amount of time. This generally means that the system was not
successful when coming up with the new code level and went back to the older
code level
Retry the operation. To do this, select Select Advanced Features and then select Install
And Activate. If the code update fails again, contact your next level
of support. |
|
| E302F874 |
Rebooting the service processor was executed, but the
system unit did not return to its original state within a reasonable amount
of time.
Go to the Server and Partition display, refresh the screen and
ensure the system is in a good state (for example, power off, standby, or
operating). If it is not in a good state, then take the necessary steps to
put it in a good state. After it is in a good state, check System Information
to ensure the code update was applied. If it is now in a good state but the
update is not applied, repeat the operation. |
|
| E302F875 |
An error occurred while attempting to query (at standby)
in an attempt to retrieve all of the updates from the removable media.
The CD or DVD may be faulty. Try another one. |
|
| E302F876 |
A failure occurred while trying to query the name of the
image in the RPM file.
Reboot the HMC and try the operation again. If
the problem occurs again, contact your next level of support. |
|
| E302F877 |
An exception occurred while trying to query the name of
the image in the RPM file.
Reboot the HMC and try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F878 |
A failure occurred trying to erase an RPM file.
Reboot
the HMC and try the operation again. If the problem occurs again, contact
your next level of support. |
|
| E302F879 |
An exception occurred trying to erase an RPM file.
Reboot the HMC and try the operation again. If the problem occurs again,
contact your next level of support. |
|
| E302F87A |
A failure occurred while trying to change the permissions
of an image file after it had been pulled from an RPM package.
Reboot the HMC
and try the operation again. If the problem occurs again, contact your next
level of support. |
|
| E302F87B |
An exception occurred while trying to change the permissions
of an image file after it had been pulled from an RPM package.
Reboot the HMC
and try the operation again. If the problem occurs again, contact your next
level of support. |
|
| E302F87C |
After the flash write to the primary service processor
was complete, the secondary service processor did not complete operations
within half an hour.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F87D |
A failure occurred importing I/O microcode.
Try the
operation again. If the problem occurs again, contact your next level of support. |
|
| E302F87E |
An IPL of the service processor was executed as part of
a disruptive firmware update, but it did not put the system in its original
state within a reasonable amount of time.
Go to the Server and Partition
display, refresh the screen and ensure the system is in a good state (for
example, power off, standby, or operating). If it is not in a good state,
take the necessary steps to put it in a good state. After it is in a good
state, check System Information to ensure the code update was applied. |
|
| E302F87F |
Powering off the service processor was executed as part
of a disruptive firmware update, but it did not put the service processor
in a powered off state within a reasonable amount of time.
Go to the Server
and Partition display, refresh the screen and ensure the system is in a good
state (for example, power off, standby, or operating). If it is not in a good
state, take the necessary steps to put it in a good state. After it is in
a good state, repeat the code update operation. |
|
| E302F880 |
Powering on the service processor was executed as part
of a disruptive firmware update, but it did not put the service processor
in a powered on state within a reasonable amount of time.
Go to the Server
and Partition display, refresh the screen and ensure the system is in a good
state (for example, power off, standby, or operating). If it is not in a good
state, take the necessary steps to put it in a good state. After it is in
a good state, check System Information to ensure the code update was applied. |
|
| E302F881 |
An IPL was executed as part of a disruptive firmware update,
but the managed system was placed in an error state.
If this message occurs,
contact your next level of support. |
|
| E302F882 |
A power off was executed as part of a disruptive firmware
update, but the managed system was placed in an error state.
If this message
occurs, contact your next level of support. |
|
| E302F883 |
A power on was executed as part of a disruptive firmware
update, but the managed system was placed in an error state.
If this message
occurs, contact your next level of support. |
|
| E302F884 |
The service processor was rebooted during a firmware update,
but it did not put the service processor in a "not connected" state within
a reasonable amount of time.
Go to the Server and Partition display, refresh
the screen and ensure the system is in a good state (for example, power off,
standby, or operating). If it is not in a good state, take the necessary steps
to put it in a good state. When in a good state, check System Information
to ensure the code update was applied. If it is now in a good state but the
update is not applied, then repeat the operation. |
|
| E302F885 |
The service processor was rebooted during a firmware update,
which put the service processor in a "not connected" state. However, this
action did not clear the "not connected" state within a reasonable amount
of time.
Contact the next level of support for assistance in getting the HMC
to communicate with the service processor again. |
|
| E302F886 |
An exception occurred during execution of the synchronous
import program while retrieving code from a repository.
If this message
occurs, contact your next level of support. |
|
| E302F887 |
An exception occurred during execution of the synchronous
apply staged updates program while applying code from the hard file staging
area.
If this message occurs, contact your next level of support. |
|
| E302F888 |
A chsyscfg command was issued to
change the next IPL side, but it failed.
Reboot the HMC and try the
operation again. If the problem occurs again, contact your next level of support. |
|
| E302F889 |
An exception occurred after a chsyscfg command was issued to change the next IPL side.
Reboot the HMC
and try the operation again. If the problem occurs again, contact your next
level of support. |
|
| E302F88A |
Powering off the system unit has started. |
|
| E302F88B |
Reading of the firmware update files has started. |
|
| E302F88C |
Writing of the firmware update files has started. |
|
| E302F88D |
Rebooting the service processor has started. |
|
| E302F88E |
Powering on the system unit has started. |
|
| E302F88F |
Restoring of the firmware update files to the P side has
started. |
|
| E302F890 |
An error occurred while attempting to find the directory
used as temporary storage.
Reboot the HMC and try the operation again.
If the problem occurs again, contact your next level of support. |
|
| E302F891 |
Failure when attempting to import an RPM package from
the IBM Web site.
Verify
that your LAN connections are set up properly and retry the operation. If
the problem occurs again, contact your next level of support. |
|
| E302F892 |
A request was received to take the service processor back
to an earlier level, but it was a concurrent request. This operation can only
be performed disruptively.
Reboot the HMC and schedule time for a disruptive
update. Retry the operation during that scheduled time. If the problem occurs
again, contact your next level of support. |
|
| E302F893 |
A general error occurred while applying code.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F894 |
A general error occurred while processing a hardware upgrade.
If another error occurs before this message, follow the action for that error.
If this message occurs by itself, contact your next level of support. |
|
| E302F895 |
A general error occurred while committing code.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F896 |
A general error occurred while exporting code to the DVD.
If another error occurs before this message, follow the action for that error.
If this message occurs by itself, contact your next level of support. |
|
| E302F897 |
A general error occurred while importing code.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F898 |
A general error occurred while rejecting code.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F899 |
An attempt was made to update the hypervisor firmware,
but the hypervisor reported that it is already at that level. |
|
| E302F89A |
A general error occurred while updating the flash
on a service processor.
If another error occurs before this message, follow
the action for that error. If this message occurs by itself, contact your
next level of support. |
|
| E302F89B |
An error occurred while swapping the T and P sides
of the secondary service processor.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F89C |
An error occurred while copying the T to the P side
on the secondary service processor.
- For systems using HMC firmware before V5R1.1, the secondary service processor
will be synchronized in the next code update. If this does not occur, contact
your next level of support.
- For systems using V5R1.1 (or newer) HMC firmware, follow the appropriate
replace and verify procedure to synchronize the secondary service processor
firmware to the primary firmware. Ensure that you set up the service processor
failover feature as desired after you complete the replace and verify procedure.
|
|
| E302F89D |
A failure occurred either writing the firmware to
the bulk power assemblies (BPAs), or rebooting them after writing the firmware.
If another error occurs before this message, follow the action for that error.
If this message occurs by itself, contact your next level of support. |
|
| E302F89E |
A failure occurred while trying to erase a file.
If another error occurs before this message, follow the action for that error.
If this message occurs by itself, contact your next level of support. |
|
| E302F89F |
An attempt to set a lock on a BPA frame failed.
The BPA is locked by another process.
Do the following as applicable:
- Make sure that you do not select multiple managed systems (that are associated
with the same power frame) for simultaneous managed system and power code
update or upgrade.
- Allow all currently running code update processes to end successfully
on all of the associated HMCs.
- Ensure that all frame numbering, frame initialization, and repair and
verify processes that also use BPA locking end successfully on all of the
associated HMCs.
- After all the operations are finished and a retargeting to one of the
managed systems still results in this error, remove the BPA lock. To remove
the BPA lock, use the following command from the HMC:
rmlock -e Frame*MTMS where Frame*MTMS is the machine-type, model,
and serial number of the affected BPA.
- Retry the operation. If the error occurs again, contact your next level
of support.
|
|
| E302F8A0 |
An error occurred while trying to read the list of fixpacks that was surveyed.
Reboot the HMC and retry the operation. If the problem occurs again, consider
replacing the disk drive of the HMC. |
|
| E302F8A1 |
An error occurred while trying to close the list of fixpacks that was surveyed.
Reboot the HMC and retry the operation. If the problem occurs again, consider
replacing the disk drive of the HMC. |
|
| E302F8A2 |
An error occurred while attempting to update the server
firmware.
Try the operation again. If the error occurs again, contact your
next level of support. |
|
| E302F8A3 |
An error occurred while querying to see if the server
firmware diff file is in memory.
Try the operation again. If the error occurs
again, contact your next level of support. |
|
| E302F8A4 |
An exception occurred while querying to see if the server
firmware diff file is in memory.
Try the operation again. If the error occurs
again, contact your next level of support. |
|
| E302F8A5 |
An exception occurred while querying to see if the HMC
is the code update owner.
Try the operation again. If the error occurs again,
contact your next level of support. |
|
| E302F8A6 |
An exception occurred while setting the HMC to be
the code update owner.
Try the operation again. If the error occurs again,
contact your next level of support. |
|
| E302F8A7 |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F8A8 |
Querying to see if the service firmware diff file is in
memory did not return the proper number of elements in the vector.
Try the
operation again. If the error occurs again, contact your next level of support. |
|
| E302F8A9 |
A general error occurred while rebooting.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F8AA |
An error occurred when attempting to copy the P-side
flash memory to the T-side on the master service processor.
Try the operation
again. If the error occurs again, contact your next level of support. |
|
| E302F8AB |
An error occurred when attempting to copy the P-side
flash memory to the T-side on the secondary service processor.
Try the operation
again. If the error occurs again, contact your next level of support. |
|
| E302F8AC to E302F8CF |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F8D0 |
An I/O error occurred while reading the fixpack image.
Reboot the HMC and
retry the operation. If the problem occurs again, consider replacing the disk
drive in the HMC. |
|
| E302F8D1 |
An error occurred while writing a firmware update file
that was read from a fixpack to disk.
Reboot the HMC and retry the operation. If the problem
occurs again, contact your next level of support. |
|
| E302F8D2 to E302F8EF |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F8F0 |
An error occurred while surveying the IBM Web site.
Verify that your LAN connections are
set up properly and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F8F1 |
An exception occurred while surveying the IBM Web site.
Verify that your LAN connections are
set up properly and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F8F2 |
An exception occurred while copying the XML file to the
cover letter during importation from the Web site.
Verify that your LAN
connections are set up properly and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F8F3 |
Two hour wait period exceeded for the updating of
firmware on the service processor in the bulk power assembly.
If another
error occurs before this message, follow the action for that error. If this
message occurs by itself, contact your next level of support. |
|
| E302F8F4 |
An error occurred while surveying the IBM Web site. The file was not found at the Web site.
Verify that the HMC connection to the IBM Web site is
working by using the information center HELP links on the local HMC master
console. Access the IBM Web site by using the links in information center that
activate the Web browser on the HMC. If the HMC cannot connect to
the IBM Web site, contact the network administrator for your installation
to determine if a firewall or other network security process must be opened
for the HMC to access the Internet. If the HMC is on a private network,
the IBM Web site will not be available as a repository. Retry the operation
again after you successfully access the IBM Web site. If the error occurs again, contact
your next level of support. |
|
| E302F8F5 to E302F8FF |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F900 |
The survey from an FTP site failed when the control
program was not able to change the directory to that of the user.
Verify
that the FTP site directory specified is correct and that any firewall authentications
were completed, if necessary, before performing the update. Try the operation
again. If the problem occurs again, contact your next level of support. |
|
| E302F901 |
A query of the current boot side of the secondary
processor returned a null.
Verify that the authentication passwords for
the service processors are synchronized and that the TCP/IP addresses of the
service processors are not in the HMC DHCP server's removed list. Use
the Update Managed System Password field under the Server and Partition panels
to reset the password if necessary. Use the restricted shell "mksysconn -o
auto" command to reset the HMC DHCP server's removed list and reconnect the
affected service processors. If the problem occurs again, contact your next
level of support. |
|
| E302F902 |
A query of the next boot side of the secondary processor
returned a null.
Verify that the authentication passwords for the service
processors are synchronized and that the TCP/IP addresses of the service processors
are not in the HMC DHCP server's removed list. Use the Update Managed System
Password pulldown under the Server and Partition panels to reset the password
if necessary. Use the restricted shell "mksysconn -o auto" command to reset
the HMC DHCP server's removed list and reconnect the affected service processors.
If the problem occurs again, contact your next level of support. |
|
| E302F903 to E302F90F |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F910 |
An exception occurred when querying to find out
if the bulk power assembly was N-mode.
Verify that both the primary and
secondary service processors for the bulk power assembly (or assemblies) are
configured properly and available for communication with the HMC. This is
a requirement. Retry the operation. If the problem occurs again, contact your
next level of support. |
|
| E302F911 |
A failure occurred when querying to find out if
the bulk power assembly was N-mode.
Verify that both the primary and secondary
service processors for the bulk power assembly (or assemblies) are configured
properly and available for communication with the HMC. This is a requirement.
Retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F912 |
One of the bulk power assemblies targeted for firmware
update has N-mode power.
Verify that both the primary and secondary service
processors for the bulk power assembly (or assemblies) are configured properly
and available for communication with the HMC. This is a requirement. Retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F913 |
One of the bulk power assemblies targeted for firmware
update has an auto-code download (ACDL) pending.
A code update cannot be
performed while a service processor in the bulk power assembly is running
an auto-code download process. Depending on the number of FRUs being loaded,
this process might take a significantly long time. After two hours, try the
original operation again. If the failure occurs again, wait two hours and
manually point the next re-IPL of the service processor to the "P" side by
using the Flash Side Selection panels. Perform a "Disruptive Activate" using
the Select advanced features panels. Wait two hours for that auto-code download
to complete, then try the original operation again. If the problem occurs
again, contact your next level of support. |
|
| E302F914 |
An exception occurred when attempting to start the
auto-code download (ACDL) on a bulk power assembly.
- For systems using HMC firmware before V5R2, contact your next level of
support.
- For systems using V5R2 (or newer) HMC firmware, do the following:
- Choose Select advanced features.
- Perform an Install and activate (implied Retrieve)
Specific Level update to the current level of power firmware on the hard
drive repository. (Choose Automatically Accept.)
- Click Change Levels, and change None to the current level of power firmware.
- Leave the Managed System code level as None, and then finish
the code update.
If the problem occurs again, contact your next level of support. |
|
| E302F915 |
A failure occurred when attempting to start the
auto-code download (ACDL) on a bulk power assembly.
- For systems using HMC firmware before V5R2, contact your next level of
support.
- For systems using V5R2 (or newer) HMC firmware, do the following:
- Choose Select advanced features.
- Perform an Install and activate (implied Retrieve)
Specific Level update to the current level of power firmware on the hard
drive repository. (Choose Automatically Accept.)
- Click Change Levels, and change None to the current level of power firmware.
- Leave the Managed System code level as None, and then finish
the code update.
If the problem occurs again, contact your next level of support. |
|
| E302F916 |
An exception occurred when attempting to determine
how many FRUs were completed during an auto-code download (ACDL).
- For systems using HMC firmware before V5R2, contact your next level of
support.
- For systems using V5R2 (or newer) HMC firmware, do the following:
- Choose Select advanced features.
- Perform an Install and activate (implied Retrieve)
Specific Level update to the current level of power firmware on the hard
drive repository. (Choose Automatically Accept.)
- Click Change Levels, and change None to the current level of power firmware.
- Leave the Managed System code level as None, and then finish
the code update.
If the problem occurs again, contact your next level of support. |
|
| E302F917 |
A failure occurred when attempting to determine
how many FRUs were completed during an auto-code download (ACDL).
- For systems using HMC firmware before V5R2, contact your next level of
support.
- For systems using V5R2 (or newer) HMC firmware, do the following:
- Choose Select advanced features.
- Perform an Install and activate (implied Retrieve)
Specific Level update to the current level of power firmware on the hard
drive repository. (Choose Automatically Accept.)
- Click Change Levels, and change None to the current level of power firmware.
- Leave the Managed System code level as None, and then finish
the code update.
If the problem occurs again, contact your next level of support. |
|
| E302F918 |
The auto-code download (ACDL) took too long on one
side of the bulk power assembly.
- For systems using HMC firmware before V5R2, contact your next level of
support.
- For systems using V5R2 (or newer) HMC firmware, do the following:
- Choose Select advanced features.
- Perform an Install and activate (implied Retrieve)
Specific Level update to the current level of power firmware on the hard
drive repository. (Choose Automatically Accept.)
- Click Change Levels, and change None to the current level of power firmware.
- Leave the Managed System code level as None, and then finish
the code update.
If the problem occurs again, contact your next level of support. |
|
| E302F919 |
The auto-code download (ACDL) began but did not
complete successfully.
Follow the actions listed for E302F918. |
|
| E302F91A |
An error occurred in the service processor support
code during a query of the state of a service processor for a frame.
Reboot
the HMC and retry the operation. If the error occurs again, contact your
next level of support. |
|
| E302F91B |
A failure occurred when attempting to query the
state of the system unit after receiving an asynchronous report that the state
had changed.
Reboot the HMC and retry the operation. If the error occurs
again, contact your next level of support. |
|
| E302F91C |
A failure occurred while copying the firmware from
the T side to the P side after a successful update of the bulk power controller
code.
Perform an "Accept" operation using the Select advanced features panels.
This operation also accepts the system unit code. If the problem occurs again,
contact your next level of support. |
|
| E302F91D |
A failure occurred when trying to deactivate a bulk
power assembly.
Reboot the HMC and retry the operation. If the error
occurs again, contact your next level of support. |
|
| E302F91E |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F91F |
An exception occurred when trying to deactivate
a bulk power assembly.
Reboot the HMC and retry the operation. If the
error occurs again, contact your next level of support. |
|
| E302F920 |
An I/O error occurred when attempting to write the
power FRU code levels to a file.
Ensure the following:
- That ample space exists in the file system that contains the /opt/ccfw
directory
- That the a user with root authority executes the following command:
dlslic -e Frame*MTMS
Note:
The dlslic command is a diagnostic aid that obtains ACDL
status and creates the bpa.frus.lst file in /opt/ccfw/data directory. After you clear the file space, if necessary, execute the dlslic command
again as a user with root authority. If the error occurs again, contact your
next level of support. |
|
| E302F921 |
An I/O error occurred when attempting to close the
file containing the Power FRU code levels.
Perform the actions for error
code E302 F920. If the error occurs again, contact your next level of support. |
|
| E302F922 |
An exception occurred when attempting to set or
release a lock on a bulk power adapter frame.
Perform the actions for error
code E302 F89F. If the error occurs again, contact your next level of support. |
|
| E302F923 |
A failure occurred during a query of the current
service processor failover state.
- If another error occurs before this message, follow the action for that
error.
- If this message occurs during a code update Health Check, correct the
condition that caused the Health Check to fail and retry the operation.
- If this message occurs by itself, contact your next level of support.
|
|
| E302F924 |
An exception occurred during the query of the current
service processor failover state.
- If another error occurs before this message, follow the action for that
error.
- If this message occurs during a code update Health Check, correct the
condition that caused the Health Check to fail and retry the operation.
- If this message occurs by itself, contact your next level of support.
|
|
| E302F925 |
A failure occurred when attempting to set the service
processor failover state with the chsyscfg command.
- If another error occurs before this message, follow the action for that
error.
- If this message occurs during a code update Health Check, correct the
condition that caused the Health Check to fail and retry the operation.
- If this message occurs by itself, contact your next level of support.
|
|
| E302F926 |
An exception occurred when attempting to set the
service processor failover state with the chsyscfg command.
Follow the actions listed for E302F925. |
|
| E302F927 |
An error occurred when attempting to acquire the
service processor lock.
Reboot the HMC and retry the operation. If the
error occurs again, contact your next level of support. |
|
| E302F928 |
A timeout error occurred when attempting to acquire
the service processor lock.
Check to see if a long running DLPAR operation
is in progress to the same managed system. If there is, wait for that operation
to complete and then perform a Disruptive Activate. If the error occurs again,
contact your next level of support. |
|
| E302F929 |
An error occurred when attempting to release the
service processor lock.
Reboot the HMC and retry the operation. If the
error occurs again, contact your next level of support. |
|
| E302F92A |
Dynamic service processor failover has been disabled.
Informational message. |
|
| E302F92B |
Dynamic service processor failover has been enabled.
Informational message. |
|
| E302F92C |
A firmware update reboot of the secondary service
processor placed it into a not connected state, but it did not clear that
state in a reasonable amount of time.
Contact the next level of support
for assistance in getting the HMC to talk to the service processor again. |
|
| E302F92D |
During readiness checking, an exception occurred
in the readBPAPowerStatus() method when attempting to determine the status
of the power subsystem.
Reboot the HMC and retry the operation. If the
error occurs again, contact your next level of support. |
|
| E302F92E |
During readiness checking, a null value was returned
by the readBPAPowerStatus() method when attempting to determine the status
of the power subsystem.
Reboot the HMC and retry the operation. If the
error occurs again, contact your next level of support. |
|
| E302F92F |
During readiness checking, an exception occurred
in the getConnectionStatus() method when attempting to determine the status
of power subsystem connections.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F930 |
During readiness checking, a null value was returned
by the getConnectionStatus() method when attempting to determine the status
of power subsystem connections.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F931 |
During readiness checking, an exception occurred
in the getState() method when attempting to determine the state of the power
subsystem.
Reboot the HMC and retry the operation. If the error occurs
again, contact your next level of support. |
|
| E302F932 |
During readiness checking, an exception occurred
in the isNModePower() method when attempting to determine the state of the
power subsystem.
Reboot the HMC and retry the operation. If the error
occurs again, contact your next level of support. |
|
| E302F933 |
During readiness checking, an exception occurred
in the getRedundantFspInfoExt() method when attempting to determine the state
of the secondary service processor.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F934 |
During readiness checking, a null value was returned
by the getRedundantFspInfoExt() method when attempting to determine the state
of the secondary service processor.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F935 |
During readiness checking, an exception occurred
in the getState() method when attempting to determine the state of the managed
system.
Reboot the HMC and retry the operation. If the error occurs
again, contact your next level of support. |
|
| E302F936 |
During readiness checking, an exception occurred
in the getConnectionStatus() method when attempting to determine the status
of service processor connections.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F937 |
During readiness checking, a null value was returned
by the getConnectionStatus() method when attempting to determine the status
of service processor connections.
Reboot the HMC and retry the operation.
If the error occurs again, contact your next level of support. |
|
| E302F938 to E302F9AA |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|
| E302F9AB |
An error occurred during the processing for the
update licensed internal code MES select level panel handler.
Reboot the HMC
and retry the operation. If the error occurs again, contact your next level
of support. |
|
| E302F9AC |
An error occurred during the processing for the
update licensed internal code main repository panel handler.
Reboot the HMC
and retry the operation. If the error occurs again, contact your next level
of support. |
|
| E302F9AD |
An error occurred during the processing for the
update licensed internal code FTPpanel panel handler.
Reboot the HMC
and retry the operation. If the error occurs again, contact your next level
of support. |
|
| E302F9AE |
An error occurred during the processing for the
update licensed internal code changeFTP panel handler.
Reboot the HMC
and retry the operation. If the error occurs again, contact your next level
of support. |
|
| E302F9AF |
An error occurred during the processing for the
advanced features task when trying to run a tasklet exit on the client to
display the license panel. The task is terminated.
Reboot the HMC and
retry the operation. If the error occurs again, contact your next level of
support. |
|
| E302F9B0 |
An error occurred during the processing for the
MES upgrade task when trying to run a tasklet exit on the client to display
the license panel. The task is terminated.
Reboot the HMC and retry
the operation. If the error occurs again, contact your next level of support. |
|
| E302F9B1 |
An error occurred during the processing for the
change internal code wizard when trying to run a tasklet exit on the client
to display the license panel. The task is terminated.
Reboot the HMC
and retry the operation. If the error occurs again, contact your next level
of support. |
|
| E302F9B2 |
Error during processing for the Change Internal Code Wizard
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9B3 |
Error during processing for an internal code method.
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9B4 to E302F9B6 |
Error during processing for an internal panel handler.
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9B7 |
Error during processing of the server side of the scheduleable
update task.
Reboot the HMC and retry the operation. If the problem
occurs again, contact your next level of support. |
|
| E302F9B8 |
Error trying to perform processing in a hardware upgrade
code path.
Reboot the HMC and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F9B9 |
Error during the main "service" processing for the server
side of the hardware upgrade task. The task has been terminated.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9BA |
Error during the main processing for the client side of
the hardware upgrade task. The task has been terminated.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9BB |
Error during the main processing for the server side of
the hardware upgrade task.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9BC |
Error during the processing of the actual non disruptive
firmware update task. The progress panel for the affected target is updated
with error message. The task continues to execute.
Reboot the HMC and
retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9BD |
Error during the main "service" processing for the server
side of the change internal code wizard subtasklet.
Reboot the HMC and
retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9BE |
Error during the main "service" processing for the server
side of the change internal code wizard1 panel handler.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9BF |
Error during the main "service" processing for the server
side of the change internal code wizard2 panel handler.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9C0 |
Error during the main "service" processing for the server
side of the change internal code wizard3 panel handler.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9C1 |
Error during the main "service" processing for the server
side of the change internal code wizard4 panel handler.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9C2 |
Error during the main "service" processing for the server
side of the change internal code wizard cecconcurrency panel handler.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9C3 |
Error during the main "service" processing for the server
side of the change internal code wizard cecdetails panel handler.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9C4 |
Error during the main "service" processing for the server
side of the change internal code wizard fix details panel handler.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9C5 |
Error during the main "service" processing for the server
side of the change internal code wizard license panel handler.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9C6 |
Error during the main "service" processing for the server
side of the change internal code wizard leveldetails panel handler.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9C7 |
Error during the main processing for the server side of
the flash side selection task.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9C8 |
Error during the main "service" processing for the server
side of the advanced features subtasklet.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9C9 |
Error during processing for the advanced features panel
handler.
Reboot the HMC and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F9CA |
Error during processing for the advanced features retrieve
panel handler.
Reboot the HMC and retry the operation. If the problem
occurs again, contact your next level of support. |
|
| E302F9CB |
Error during processing for the advanced features implied
retrieve panel handler.
Reboot the HMC and retry the operation. If the
problem occurs again, contact your next level of support. |
|
| E302F9CC |
Error during processing for the advanced features change
levels panel handler.
Reboot the HMC and retry the operation. If the
problem occurs again, contact your next level of support. |
|
| E302F9CD |
Error during processing for the advanced features select
change levels panel handler.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9CE |
Error during processing for the advanced features install
type panel handler.
Reboot the HMC and retry the operation. If the problem
occurs again, contact your next level of support. |
|
| E302F9CF |
Error during processing for the advanced features fix
details panel handler.
Reboot the HMC and retry the operation. If the
problem occurs again, contact your next level of support. |
|
| E302F9D0 |
Error during processing for the advanced features confirm
panel handler.
Reboot the HMC and retry the operation. If the problem
occurs again, contact your next level of support. |
|
| E302F9D1 |
Error during processing for the advanced features level
details panel handler.
Reboot the HMC and retry the operation. If the
problem occurs again, contact your next level of support. |
|
| E302F9D2 |
Error during the main "service" processing for the server
side of the change internal code task. The task is terminated.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9D3 |
Error during processing change internal code MainPanel
panel handler. The task is terminated.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9D4 |
Error during processing change internal code MainRepos
panel handler. The task is terminated.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9D5 |
Error during processing change internal code InbandMessage
panel handler. The task is terminated.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9D6 |
Error during processing change internal code FtpPanel
panel handler. The task is terminated.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9D7 |
Error during processing change internal code ChangeFTP
panel handler. The task is terminated.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9D8 |
Error trying to assign values from a SysInfoEcInternalCodeData
object.
Reboot the HMC and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F9D9 |
Error during the main processing for the server side of
the system information task.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9DA |
Error from getting null presentation task parameters in
the system information task.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9DB |
Error during the processing for the server side SysInfoEcTasklet
system information subtask.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9DC |
Error trying to do the main processing for the client
side of the change internal code task. The task has been terminated.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9DD |
Error trying to do the main processing for the client
side of the flash side selection task. The task has been terminated.
Reboot
the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9DE |
Error trying to do the main processing for the client
side of the non disruptive firmware update task. The task has been terminated.
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9DF |
Error during the main processing for the server side of
the advanced features subtask.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9E0 |
Error during the main processing for the server side of
the advanced targeting subtask.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9E1 |
Error during the main processing for the server side of
the Change Internal Code task. This could be the result of an exception being
caught by the underlying tasklet infrastructure.
Reboot the HMC and
retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9E2 |
Error during the main processing for the server side of
the Nondisruptive Firmware Update task. This could be the result of an exception
being caught by the underlying tasklet infrastructure.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9E3 |
Error during the main processing for the server side of
the Change Internal Code Wizard subtask. This could be the result of an exception
being caught by the underlying tasklet infrastructure.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9E4 |
Error trying to perform some processing in the Advanced
Features Bean panelAction() method. The bean attempts to close the panel.
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9E5 |
Error trying to perform some processing in the Advanced
Targeting for Frames Bean panelAction() method. The bean attempts to close
the panel.
Reboot the HMC and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F9E6 |
Error trying to perform some processing in the Advanced
Targeting for System Bean panelAction() method. The bean attempts to close
the panel.
Reboot the HMC and retry the operation. If the problem occurs
again, contact your next level of support. |
|
| E302F9E7 |
Error in the select advanced targeting type bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9E8 |
Error in the CEC/power concurrency bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9E9 |
Error in the CEC/power level details bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9EA |
Error in the change FTP directory bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9EB |
Error in the specify levels bean panelAction method. This
bean attempts to close the panel.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9EC |
Error in the advanced features confirm bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9ED |
Error in the LIC details bean panelAction method. This
bean attempts to close the panel.
Reboot the HMC and retry the operation.
If the problem occurs again, contact your next level of support. |
|
| E302F9EE |
Error in the flash side selection bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9EF |
Error in the FTP site access bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F0 |
Error in the advanced features install and activate (implied
retrieval) bean panelAction method. This bean attempts to close the panel.
Reboot the HMC and retry the operation. If the problem occurs again, contact
your next level of support. |
|
| E302F9F1 |
Error in the inband configuration detected bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F2 |
Error in the advanced features select installation type
bean panelAction method. This bean attempts to close the panel.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9F3 |
Error in the confirmation level details bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F4 |
Error in the license agreement bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F5 |
Error in the change internal code main bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F6 |
Error in the change internal code main repos bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F7 |
Error in the nondisruptive firmware update bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F8 |
Error in the advanced features retrieve bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9F9 |
Error in the select advanced targeting frame choice bean
panelAction method. This bean attempts to close the panel.
Reboot the HMC
and retry the operation. If the problem occurs again, contact your next level
of support. |
|
| E302F9FA |
Error in the advanced features select level bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9FB |
Error in the system information bean panelAction method.
This bean attempts to close the panel.
Reboot the HMC and retry the
operation. If the problem occurs again, contact your next level of support. |
|
| E302F9FC |
Error in the change internal code wizard1 bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9FD |
Error in the change internal code wizard2 bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9FE |
Error in the change internal code wizard3 bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302F9FF |
Error in the change internal code wizard4 bean panelAction
method. This bean attempts to close the panel.
Reboot the HMC and retry
the operation. If the problem occurs again, contact your next level of support. |
|
| E302FA00 |
An error occurred while attempting to synchronize
one service processor to the other during a repair and verify operation.
Ensure that the entire repair and verify procedure executed correctly and
that the new service processor is communicating properly. If the error continues
to occur, contact your next level of support. |
|
| E302FA01 |
An error occurred while attempting to determine
which service processor is the source and which one is the destination for
a repair and verify operation.
Ensure that the entire repair and verify
procedure executed correctly and that the new service processor is communicating
properly. If the error continues to occur, contact your next level of support. |
|
| E302FA02 |
An error occurred while attempting to create a targeted
service processor object during a repair and verify operation.
Ensure that
the entire repair and verify procedure executed correctly and that the new
service processor is communicating properly. If the error continues to occur,
contact your next level of support. |
|
| E302FA03 to E302FFFF |
Licensed Internal Code failure on the HMC.
Contact your service provider. |
|