Procedure
- Attach the electrostatic discharge
(ESD) wrist strap.
Attention: - Attach an electrostatic discharge (ESD)
wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your
hardware to prevent the electrostatic discharge from damaging your hardware.
- When you use an ESD wrist strap, follow all
electrical safety procedures. An ESD wrist strap is used for static control. It does not increase or
decrease your risk of receiving electric shock when using or working on electrical
equipment.
- If you do not have an ESD wrist strap, just prior
to removing the product from ESD packaging and installing or replacing hardware, touch an unpainted
metal surface of the system for a minimum of 5 seconds.
- Remove the front USB signal
cable from the system backplane,
as shown in Figure 1.
Figure 1. Disconnecting the front USB
cable
- Remove the disk drive backplane. For instructions, see Removing the disk drive backplane from the 8348-21C.
- Label and fully remove the three leftmost front drive trays that are located next to the front
USB port. For instructions, see Removing a front drive in the 8348-21C.
- Remove the four screws that secure the USB bezel and handle to the USB front assembly, as shown
in Figure 2.
Figure 2. Removing the front USB and cable
- Remove the two screws that secure the USB assembly to the side of the chassis, as shown in
Figure 2.
- Pull the USB assembly forward, then detach the USB assembly away from the pins in the side of
the chassis, as shown in Figure 2.
- Remove the front USB and cable from the chassis.
- Remove the two screws (A) from the USB card (B);
then lift the USB card and cable away from the holder, as shown in Figure 3.
Figure 3. Removing the USB card