POWER7 information

8236-E8C ENERGY STAR® Power and Performance Data Sheet

IBM® 8236-E8C

Energy Star
Table 1. System Characteristics
System Characteristics  
Form Factor 4U Rackmount
Available Processor Sockets 4
Available DIMM Slots / Max Memory Capacity 32 / 256 GB
ECC and/or Fully Buffered DIMMs Yes
Available Expansion Slots 3 PCIe, 2 PCI-X
Minimum and Maximum # of Hard Drives 1 to 8
Redundant Power Supply Capable? Yes
Power Supply Make and Model Emerson Network Power 7001520-J000
Power Supply Output Rating* (watts) 1725
Minimum and Maximum # of Power Supplies 2 and 2
Input Power Range (AC or DC) 200-240 VAC
Power Supply Efficiency at Specified Loadings* 85.2@10%, 90.6@20%, 92.2@50%, 89.2@100%
Power Supply Power Factor at Specified Loadings* 0.88@10%, 0.96@20%, 0.99@50%, 0.99@100%
Operating Systems Supported AIX® 6.1H, Linux SLES 1
Installed Operating System for Testing AIX 6.1H

* Note: Power supply information is for a single power supply only

Table 2. System Configurations
System Configurations Minimum Typical Maximum
Configuration ID 4 x 8332 4 x 8332 4 x 8332
Processor Information 4 x 8-core 3.3 GHz POWER7® processor card 4 x 8-core 3.3 GHz POWER7 processor card 4 x 8-core 3.3 GHz POWER7 processor card
Memory Information 32 x 8GB DIMMs, 1067 MHz, 2Gb DDR3 DRAM 32 x 8GB DIMMs, 1067 MHz, 2Gb DDR3 DRAM 32 x 8GB DIMMs, 1067 MHz, 2Gb DDR3 DRAM
Internal Storage 1 x 2.5 inch, 15 kRPM SAS 4 x 2.5 inch, 15 kRPM SAS 8 x 2.5 inch, 15 kRPM SAS
I/O Devices 1 x 2-Port 1Gb Integrated Virtual Ethernet, 1 x GX Dual-port 12X Channel Adapter 1 x 2-Port 1Gb Integrated Virtual Ethernet, 1 x GX Dual-port 12X Channel Adapter, 1 x 2-Port 10/100/1000 Base-TX Ethernet, 1 x 4 Gigabit Single Port Fibre Channel Adapter 1 x 2-Port 1Gb Integrated Virtual Ethernet, 1 x GX Dual-port 12X Channel Adapter, 1 x 2-Port 10/100/1000 Base-TX Ethernet, 3 x 4 Gigabit Single Port Fibre Channel Adapter
Power Supply Number and Redundancy Configuration 2 2 2
Management Controller or Service Processor Installed? Yes Yes Yes
Other Hardware Features / Accessories DVD-ROM DVD-ROM DVD-ROM
Table 3. Power Data
Power Data Minimum Typical Maximum
Idle Category (1S and 2S only) N/A (3S or 4S)
ENERGY STAR Idle Power Allowance (1S and 2S only) N/A N/A N/A
Measured Idle Power (watts) 796 824 859
Power at Full Load* (watts) 1178 1220 1272
Benchmark / Method Used for Full Load Test LINPACK
Test Voltage and Frequency for Idle and Full Load Test 230V 50Hz
Range of Total Estimated Energy Usage ** (kWh/year) 13,946 to 20,639 14,436 to 21,374 15,050 to 22,285
Link to Detailed Power Calculator (if available) http://www-912.ibm.com/see/EnergyEstimator

* Note: Full load power represents the sustained, average power at 100% load of the given workload, and does not necessarily represent the absolute peak power or the highest average, sustained power possible for other workloads.

** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x7x365) and ranges from 100% Idle usage to 100% full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2.0). Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e.g., average time at Idle, data center PUE, etc.).

Table 4. Power and Performance for Benchmark #1
Power and Performance for Benchmark #1 Minimum Typical Maximum
Benchmark Used and Type of Workload LINPACK
Avg. Power Measured During Benchmark Run 1178 Watts 1220 Watts 1272 Watts
Benchmark Performance Score 743.3 Gflops 743.3 Gflops 743.3 Gflops
Power Performance Ratio (perf score/avg. power) 0.631 0.609 0.584
Link to Full Benchmark Report (Where Available)      
Table 5. Power Saving Features
Power Saving Features Enabled on Shipment End-User Enabling Required
Processor Dynamic Voltage and Frequency Scaling No Yes
Processor or Core Reduced Power States Yes No
Power Capping No Yes
Variable Speed Fan Control Based on Power or Thermal Readings Yes No
Low Power Memory States No No
Low Power I/O States Yes No
Liquid Cooling Capability No No
Other1:    
Other2:    
Other3:    
Other4:    
Table 6. Power and Temperature Measurement and Reporting
Power and Temperature Measurement and Reporting  
Input Power Available & Accuracy? Yes, +/- 3%
Input Air Temp Available & Accuracy? Yes, +/- 1°C typical, +/- 2°C maximum
Processor Utilization Available? Yes
Other Data Measurements Available & Accuracy?  
Compatible Protocols for Data Collection REST
Averaging method and time period 30 second average, 1 second peak
Table 7. Thermal Information*
Thermal Information* Minimum Typical Maximum
Total Power Dissipation (watts) 1178 1220 1272
Delta Temperature at Exhaust at Peak Temp. (˚C) 9.4 9.8 10.2
Airflow at Maximum Fan Speed (CFM) at Peak Temp. 220 220 220
Airflow at Nominal Fan Speed (CFM) at Nominal Temp. 130 130 130

* References: ASHRAE Extended Environmental Envelope Final August 1, 2008

Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5

Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C

Notes:

1. SPECpower_ssj2008 is a registered trademark of the Standard Performance Evaluation Corporation (SPEC). Benchmark results stated above reflect results published on XX/XX/XX. For the latest SPECpower_ssj2008 benchmark results, visit http://www.spec.org/power_ssj2008.



Send feedback Rate this page

Last updated: Thu, March 15, 2018