POWER7 information

5886 locations

Use this information to help you map a location code to a position on the unit.

Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.

The following diagrams show the field replaceable unit (FRU) layout in the system. Use these diagrams with the following tables.

Figure 1. Front and rear views
Front and rear views

The following table provides location codes for parts that make up the server.

Table 1. FRU locations and failing components
Failing item name Physical location code Identify LED Failing item removal and replacement procedures
System unit Un    
ESM
ESM A Un-C1 Yes See Enclosure services manager.
ESM B Un-C2 Yes
Power supplies
Power supply Un-E1 Yes See Power supply.
Power supply Un-E2 Yes
Midplane
Midplane Un-P1 Yes See Midplane.
Device physical locations
Disk drive 1 Un-P1-D1 Yes See Disk unit.
Disk drive 2 Un-P1-D2 Yes
Disk drive 3 Un-P1-D3 Yes
Disk drive 4 Un-P1-D4 Yes
Disk drive 5 Un-P1-D5 Yes
Disk drive 6 Un-P1-D6 Yes
Disk drive 7 Un-P1-D7 Yes
Disk drive 8 Un-P1-D8 Yes
Disk drive 9 Un-P1-D9 Yes
Disk drive 10 Un-P1-D10 Yes
Disk drive 11 Un-P1-D11 Yes
Disk drive 12 Un-P1-D12 Yes


Send feedback Rate this page

Last updated: Fri, June 07, 2019