Use this MAP to check out the server after a repair is completed.
Use this MAP to check out the server after a repair is completed.
If you are servicing an SP system, go to the End-of-call MAP in the SP System Service Guide.
If you are servicing a clustered system, go to the End of Call MAP in the Clustered eServer™ Installation and Service Guide.
Do you have any FRUs (for example cards, adapters, cables, or devices) that were removed during problem analysis that you want to put back into the system?
Is the system or logical partition that you are performing a repair action on running the AIX® operating system?
Run standalone diagnostics from either a CD ROM or from a NIM server.
System: |
Action: |
|---|---|
8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, 8205-E6D, 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, 8248-L4T, 8268-E1D, 8408-E8D, 9109-RMD, or 9119-FHB |
Perform a normal boot.
Note: Slow boot is
not supported.
|
8233-E8B or 8236-E8C |
Determine the level
of firmware the system
is running.
Is system firmware AL710_xxx installed?
|
8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD |
Determine the level
of firmware the system
is running.
Is system firmware AM710_xxx installed?
|
Did the AIX Login Prompt display?
If the Resource Repair Action menu is already displayed, go to Step 0410-10; otherwise, do the following:
Did the TESTING COMPLETE, no trouble was found menu (801010) display?
If the resource associated with your action is not displayed on the resource list, select sysplanar0.
Go to Step 0410-12.
When a test is run on a resource in system verification mode, and that resource has an entry in the AIX error log, if the test on the resource was successful, the RESOURCE REPAIR ACTION menu displays.
After replacing a FRU, you must select the resource for that FRU from the RESOURCE REPAIR ACTION menu. This updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Do the following:
The parent or child of the resource you just replaced may also require that you run the RESOURCE REPAIR ACTION service aid on it.
When a test is run on a resource in system verification mode, and that resource has an entry in the AIX error log, if the test on the resource was successful, the RESOURCE REPAIR ACTION menu displays.
After replacing that FRU, you must select the resource for that FRU from the RESOURCE REPAIR ACTION menu. This updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Do the following:
If you changed the service processor or network settings, as instructed in previous MAPs, restore the settings to the value they had prior to servicing the system. If you ran standalone diagnostics from CD-ROM, remove the standalone diagnostics CD-ROM from the system.
Use the Recover Options selection to resolve the RAID configuration. To do this, do the following:
If the system you are servicing has a management console, go to the end-of-call procedure for systems with Service Focal Point™.
This completes the repair; return the server to the customer.